VB-5241 Omron, VB-5241 Datasheet - Page 2

no-image

VB-5241

Manufacturer Part Number
VB-5241
Description
SWITCH LIMIT SPDT 10A ROLL PLNGR
Manufacturer
Omron
Series
VBr
Datasheet

Specifications of VB-5241

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Roller Plunger
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
1471gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
VB5241
Specifications
Approved Standards
Ratings
Standard Model
Note: The above currents are steady-state currents.
Micro Load Ratings
Approved Standard Ratings
TÜV (EN60947-5-1) (Grand terminal models only)
Standard Model
Micro Load Model
CCC (GB14048.5)
TÜV Rheinland
CCC (CQC)
Inrush
current
Rated operating current (Ie)
Rated operating voltage (Ue)
Rated operating current (Ie)
Rated operating voltage (Ue)
Agency
Applicable category
Applicable category
Rated voltage
Rated voltage
125 VAC
250 VAC
125 VDC
250 VDC
125 VAC
30 VDC
8 VDC
NC
NO
EN60947-5-1
(IEC947-5-1)
GB14048.5
Standards
Applicable category and ratings
AC-15 2 A/250 VAC
J50062491
2003010305077628
0.1 A
File No.
AC-15
AC-14
250 V
125 V
0.1 A
NC
2 A
Resistive load
Resistive load
24 A max.
24 A max.
0.6 A
0.3 A
10 A
10 A
Only models with
ground terminals
Ask your OMRON
representative for
information on
approved models.
Approved models
DC-15
DC-15
0.1 A
48 V
30 V
NO
2 A
Characteristics
Note: The above values are initial values.
* The values are calculated at an operating temperature of 5°C to
Engineering Data
Electrical Durability (with more than 300,000
Operations)
(Ambient temperature: 5
Degree of protection
Durability *
Operating speed
Operating
frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric
strength
Rated insulation voltage (U
Switching overvoltage
Pollution degree
(operating environment)
Short-circuit protective device
(SCPD)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal
current (I
Protection against electric
shock
Vibration
resistance
Shock
resistance
Ambient operating temperature
Ambient operating humidity
Weight
35°C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on
other operating environments.
the
)
Mechanical
Electrical
Mechanical
Electrical
Between terminals
of same polarity
Between current-
carrying metal
parts and ground
Between each
terminal and non-
current-carrying
metal part
Between terminals
of different
polarity
Malfunction
Destruction
Malfunction
1,000
700
500
300
200
100
70
50
30
10
0
0.5
°C
i
)
to 35
1
Switching current (A)
2
°C
3
IP67
5,000,000 operations min.
300,000 operations min.
(10 A at 250 VAC, resistive load)
0.1 mm to 0.5 m/s
120 operations min.
30 operations min.
50/60 Hz (AC)
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
1,000 VAC/U
1,500 VAC/U
1,500 VAC/U
U
300 VAC (EN60947-5-1)
1,000 V max. (EN60947-5-1)
3 (EN60947-5-1)
10 A fuse type gG or gI (IEC269)
5 A, 0.5 A (EN60947-5-1)
Insulation class I (Use the grounding
terminal or ground on the machine side.)
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s
200 m/s
–10°C to 80°C (with no icing)
35% to 95%
Approx. 580 g (in the case of VB-4211)
imp
; Ambient humidity: 40% to 70%)
4
4 kV (EN60947-5-1)
5
Operating frequency:
30 operations/min
250 VAC, cosφ = 1
2
6 7
min.
2
min.
imp
imp
imp
8
4,000 VAC
4,000 VAC
4,000 VAC
9
10
11
12
VB
2