EA STARTEDIPTFT4 ELECTRONIC ASSEMBLY, EA STARTEDIPTFT4 Datasheet - Page 11

TFT Displays & Accessories Starter/Demoboard w/Touch USB prog

EA STARTEDIPTFT4

Manufacturer Part Number
EA STARTEDIPTFT4
Description
TFT Displays & Accessories Starter/Demoboard w/Touch USB prog
Manufacturer
ELECTRONIC ASSEMBLY
Datasheet

Specifications of EA STARTEDIPTFT4

Attached Touch Screen
Yes
Background Color
White
Interface
I2C, SPI, RS-232
Interface Type
RS-232, I2C, SPI
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 20 C
Operating Temperature Range
- 20 C to + 70 C
Supply Voltage
5 V
Touch Panel
Touch Panel
Viewing Area (w X H)
53.86 mm x 95.04 mm
Module Size (w X H X T)
71 mm x 107 mm x 12 mm
Backlighting
LED
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ELECTRONIC ASSEMBLY reserves
the right to change specifications
without prior notice. Printing and
typographical
Request for buffer information
<DC2> = 18(dec.) = $12
<ACK> = 6(dec.) = $06
send buffer bytes ready = count of bytes stored in send buffer
receive buffer bytes free = count of bytes for free receive buffer
bcc = 1 byte = sum of all bytes incl. <DC2>, modulo 256
Protocol settings
<DC2> = 18(dec.) = $12
packet size for send buffer = 1..128 (standard: 128)
timeout = 1..255 in 1/100 seconds (standard: 200 = 2 seconds)
bcc = 1 byte = sum of all bytes incl. <DC2>, modulo 256
<ACK> = 6(dec.) = $06
Request for protocol settings
<DC2> = 18(dec.) = $12
<ACK> = 6(dec.) = $06
max. packet size = count of maximum user data for 1 package (eDIPTFT43-A = 255)
akt. send packet size = current package size for send
akt. timeout = current timeout in 1/100 seconds
bcc = 1 byte = sum of all bytes incl. <DC2>, modulo 256
Repeat the last package
<DC2> = 18(dec.) = $12
<ACK> = 6(dec.) = $06
<DC1> = 17(dec.) = $11
len = count of user data in byte (without ckecksum, without <DC1> or <DC2>)
bcc = 1 byte = sum of all bytes incl. <DC2> and len, modulo 256
Adressing (only for RS232/RS485)
<DC2> = 18(dec.) = $12
select or deselect: 'S' = $53 or 'D' = $44
adr = 0..255
bcc = 1 byte = sum of all bytes incl. <DC2> and adr, modulo 256
<ACK> = 6(dec.) = $06
>
<
<
>
<
>
<
<
>
<
<
>
<
<DC2>
<ACK>
<DC2>
<DC2>
<ACK>
<DC2>
<ACK>
<DC2>
<DC2>
<ACK>
<DC1>
<DC2>
<DC2>
<ACK>
errors
len
1
2
3
1
3
1
3
reserved.
bytes ready
packet size
send buffer
D
P
R
A
I
1 = 1(dez.) = $01
3 = 3(dez.) = $03
1 = 1(dez.) = $01
1 = 1(dez.) = $01
3 = 3(dez.) = $03
max.
packet size for
bcc
bcc
bcc
send buffer
select or
deselect
data...
receive buffer
packet size
bytes free
akt. send
I = 73(dez.) = $49
D = 68(dez.) = $44
P = 80(dez.) = $50
R = 82(dez.) = $52
A = 65(dez.) = $41
timeout
adr
bcc
bcc
akt. timeout
bcc
bcc
bcc
This command queries whether user data is
ready to be picked up an how full the display's
receive buffer is.
This is how the maximum package size that can
be sent by the display can be limited. The default
setting is a package size with up to 128 bytes of
user data.
The timeout can be set in increments of 1/100
seconds. The timeout is activated when
individual bytes get lost. The entire package
then has to be sent again.
This command is used to query protocol
settings.
If the most recently requested package
contains an incorrect checksum, the entire
package can be requested again. The reply can
then be the contents of the send buffer (<DC1>)
or the buffer/protocol information (<DC2>).
This command can be used to select or
deselect the eDIP with the address adr.
EA eDIPTFT43-A
Page 11

Related parts for EA STARTEDIPTFT4