B43540A2687M000 EPCOS Inc, B43540A2687M000 Datasheet - Page 14

Aluminum Electrolytic Capacitors - Snap In 680UF 200V AL-ELKO SNAP IN

B43540A2687M000

Manufacturer Part Number
B43540A2687M000
Description
Aluminum Electrolytic Capacitors - Snap In 680UF 200V AL-ELKO SNAP IN
Manufacturer
EPCOS Inc
Series
B43540r
Datasheet

Specifications of B43540A2687M000

Esr
120 mOhms
Operating Temperature Range
- 40 C to + 85 C
Diameter
25.4 mm (1 in)
Length
40 mm
Product
Aluminum Electrolytic Capacitors
Load Life
10000 Hrs
Termination Style
Snap In
Capacitance
680 uF
Tolerance
20 %
Voltage Rating
200 Volts
Lead Spacing
10 mm
Number Of Pins
2, 3
Ripple Current
2.58 Amps
Test Frequency
100 Hz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B43540A2687M000
Manufacturer:
EPCOS
Quantity:
30 000
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling Al electrolytic capacitors:
Please read Cautions and warnings and
Important notes at the end of this document.
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
B43540
Outstanding ripple current
Page 14 of 19
85 C

Related parts for B43540A2687M000