G6Z-1F-A-DC5 Omron, G6Z-1F-A-DC5 Datasheet - Page 5

Low Signal Relays - PCB NL 5VDC 50 Ohm Y terminal 2.6GHz

G6Z-1F-A-DC5

Manufacturer Part Number
G6Z-1F-A-DC5
Description
Low Signal Relays - PCB NL 5VDC 50 Ohm Y terminal 2.6GHz
Manufacturer
Omron
Series
G6Zr
Datasheets

Specifications of G6Z-1F-A-DC5

Contact Form
1 Form C
Coil Voltage
5 VDC
Coil Current
40 mA
Coil Type
Non-Latching
Power Consumption
200 mW
Termination Style
Solder Terminal
Isolation
60 dB to 65 dB at 900 MHz / 30 dB to 45 dB at 2.6 GHz
Insertion Loss
0.1 dB to 0.2 dB at 900 MHz / 0.3 dB to 0.5 dB at 2.6 GHz
Maximum Switching Current
0.5 A
Coil Frequency Max
2.6GHz
Coil Voltage Vdc Nom
5V
Contact Current Max
500mA
Contact Voltage Ac Nom
30V
Contact Voltage Dc Nom
30V
Coil Resistance
125ohm
Contact Configuration
SPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
5DC, G6Z-1FA G6Z1FA5DC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6Z-1F-A-DC5
Manufacturer:
samtec
Quantity:
3
G6Z
I
Note:
Note:
Engineering Data
122
Contact resistance (See note 1.)
Operating (set) time (See note 2.)
Release (reset) time (See note 2.)
Minimum set/reset pulse time
Insulation resistance (See note 3.)
Dielectric
strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Ambient Temperature vs.
Maximum Voltage
250
200
150
100
Characteristics
50
0
−40
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
−20
the dielectric strength.
0
Coil and contacts
Coil and ground, contacts
and ground
Contacts of same polarity
Item
20
Ambient temperature (°C)
40
60
G6Z
G6ZU
G6ZK
80
100
100 m Ω max.
10 ms max. (approx. 3.5 ms) 10 ms max. (approx. 2.5 ms)
10 ms max. (approx. 2.5 ms)
---
100 M Ω min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
Destruction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:1,000 m/s
Malfunction:500 m/s
Mechanical:1,000,000 operations min. (at 36,000 operations/hour)
Electrical: 300,000 operations min. (30 VAC, 10 mA/30 VDC, 10 mA), 100,000 operations
Operating: − 40 ° C to 70 ° C (with no icing or condensation)
Operating: 5% to 85%
Approx. 2.8 g
Ambient Temperature vs. Must
Operate or Must Release Voltage
Single-side stable models
100
G6Z-1P(E), G6Z-1F(E)
90
80
70
60
50
40
30
20
10
0
−60
Sample: G6Z-1P 5 VDC
Number of relays: 5
−40
min. (900 MHz, 10 W) at a switching frequency of 1,800 operations/hour
−20
0
2
2
20
Ambient temperature (°C)
Max. estimated value
40
12 ms
G6ZU-1P(E), G6ZU-1F(E)
Single-winding latching
60
Must operate voltage
Must release voltage
80 100
max.
max.
avg.
min.
avg.
min.
models
Shock direction
Y'
Conditions: Shock is applied in ±X, ±Y, and ±Z
Y
Shock Malfunction
1,000
1,000
X
Z'
X
X'
Z
Z'
directions three times each with and
without energizing the Relays to check
for contact malfunctions.
Double-winding latching
G6ZK-1P(E), G6ZK-1F(E)
1,000
200
400
600
800
Y
Y'
1,000
800
600
400
200
Not
energized
Unit:
Sample: G6Z-1P-A 50 Ω
Number of relays: 5
models
Energized
m/s
5 VDC
1,000
1,000
2
Z
X'
G6Z

Related parts for G6Z-1F-A-DC5