J134DM4-26M TELEDYNE, J134DM4-26M Datasheet - Page 2

RF (Radio Frequency) Relays DPDT 26.5VDC 3200ohm w/diode & M4 pad

J134DM4-26M

Manufacturer Part Number
J134DM4-26M
Description
RF (Radio Frequency) Relays DPDT 26.5VDC 3200ohm w/diode & M4 pad
Manufacturer
TELEDYNE
Series
134r
Datasheet

Specifications of J134DM4-26M

Contact Form
2 Form C (DPDT)
Coil Voltage
26.5 VDC
Termination Style
PCB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
©2003 TELEDYNE RELAYS
SERIES 134
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
PERFORMANCE CURVES
(NOTE 2)
Contact Arrangement
Rated Duty
Contact Resistance
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Contact Load Ratings (AC)
Contact Life Ratings
Contact Overload Rating
Contact Carry Rating
Coil Operating Power
Operate Time
Release Time
Contact Bounce
Intercontact Capacitance
Insulation Resistance
Dielectric Strength
Negative Coil Transient (Vdc)
Diode P.I.V. (Vdc)
Coil Voltage (Vdc)
Coil Resistance
(Ohms ±10% @25°C)
Coil Current (mAdc @25°C)
(134DD Series)
Pick-up Voltage (Vdc, Max.)
Drop-out Voltage (Vdc)
10
20
30
40
50
60
70
.1
.2
.3
.4
0
.01
TYPICAL RF PERFORMANCE
0.5
FREQUENCY (GHz)
(See Note 8 for full P/N example)
FIGURE 1
.1
134, 134D
134DD
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
Continuous
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Resistive:
Inductive:
Lamp:
Low Level:
Resistive:
2A/28Vdc Resistive (100 cycles min.)
Contact factory
200 milliwatts typical at nominal rated voltage @ 25°C
4.0 msec max. at nominal rated coil voltage
134 Series: 2.0 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 Vrms/60Hz
10,000,000 cycles (typical) at low level
2 Form C (DPDT)
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
134D, 134DD
134D, 134DD
BASE PART
.5
134DD (Note 4)
NUMBERS
134, 134D
134, 134D
1.0
134DD
Nom.
Max.
1.92
1.22
1.07
1.02
1.01
1.00
1.00
1 Amp/28Vdc
200 mA/28Vdc (320 mH)
100 mA/28Vdc
10 to 50 μA/10 to 50mV
250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Max.
Max.
Max.
Min.
Min.
Min.
www.teledynerelays.com
134D, 134DD Series: 7.5 msec max.
134DD-5
134D-5
134-5
56.8
78.1
0.12
100
5.0
7.5
3.5
3.7
2.5
0.7
2.6
64
300
250
200
150
100
50
0
134DD-6
0.1
134D-6
134-6
10.0
36.3
48.9
0.18
200
125
6.0
4.5
4.8
3.2
0.8
3.0
0.2
TYPICAL DC CONTACT RATING (RESISTIVE)
0.3
134DD-9
134D-9
134-9
15.0
18.1
23.6
0.35
LOAD CURRENT (AMPS DC)
400
400
9.0
6.8
8.0
4.9
0.9
4.5
0.4
70,000 ft.: 125 Vrms/60Hz
FIGURE 2
0.5
134DD-12
134D-12
134-12
12.0
20.0
12.5
16.0
11.0
0.41
800
800
9.0
6.5
1.0
5.8
0.6
100 min.
1.0 max
0.7
134DD-18
134D-18
134-18
1600
1600
18.0
30.0
12.2
13.5
14.5
0.59
10.0
9.6
1.1
9.0
0.8
134 Page 2
0.9
134DD-26
134D-26
134/1203/Q1
134-26
3200
3200
26.5
40.0
18.0
19.0
0.89
13.0
13.0
7.2
9.0
1.3
1.0

Related parts for J134DM4-26M