AWM2100V Honeywell, AWM2100V Datasheet

no-image

AWM2100V

Manufacturer Part Number
AWM2100V
Description
Flow Sensors +/-200 sccm Straight
Manufacturer
Honeywell
Datasheets

Specifications of AWM2100V

Sensor Type
Air Flow
Rated Range
+/- 200 cm/min
Accuracy/reliability
+/- 0.35 % Reading
Analog Output
30 mV
Supply Voltage
10 V
Brand/series
AWM2000
Function
AirFlow
Output
Voltage
Primary Type
AirFlow
Range, Measurement
±200 sccm
Technology
Thermal Conductive
Termination
Leaded
Voltage, Supply
15 VDC
Voltage, Switching
30 mV
Operating Temperature
–13° to +185°F
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AWM2100V
Manufacturer:
HONEYWELL
Quantity:
20 000
AWM2100V
Actual product appearance may vary.
Description
The AWM2000 Series microbridge mass airflow sensor is a passive device
comprised of two Wheatstone bridges. The heater control circuit is required for
operation per specifications. The sensing bridge supply circuit is also required for
operation per specifications. These two circuits are not on board the package and
must be supplied in the application. The differential amplifier is a useful interface
for the sensing bridge. It can be used to introduce gain and to voltage offsets to
the sensor output.
Features
sensing
CAUTION
PRODUCT DAMAGE
AWM Series Microbridge Mass Airflow Sensors are not designed to sense
liquid flow and will be damaged by liquid flow through the sensor.
Failure to comply with these instructions could result in product
damage.
Bidirectional sensing capability
Actual mass air flow sensing
Low differential pressure
Airflow Sensor, Signal Conditioning:
Unamplified (mV); Flow/Pressure
Range: ±200 sccm; Port Style: Straight
Potential Applications
ventilation, and air conditioning
systems
Damper control for heating,
Gas analyzers
Low vacuum control
Process control
Medical respirators and ventilators
Oxygen concentrators
Leak detection equipment
Vent hoods
Anesthesia control
Gas metering
Gas chromatography

Related parts for AWM2100V

AWM2100V Summary of contents

Page 1

... AWM2100V Airflow Sensor, Signal Conditioning: Unamplified (mV); Flow/Pressure Range: ±200 sccm; Port Style: Straight Actual product appearance may vary. Features Bidirectional sensing capability Actual mass air flow sensing Low differential pressure sensing Description The AWM2000 Series microbridge mass airflow sensor is a passive device comprised of two Wheatstone bridges ...

Page 2

... Signal Conditioning Flow/Pressure Range Output Voltage @ Trim Point Port Style Series Name Null Shift over Temperature Output Shift over Temperature Maximum change in flow rate Max. Repeatability & Hysteresis Error Null Offset Response Time Supply Voltage Maximum Common Mode Pressure Power Consumption ...