19C500PG4K Honeywell, 19C500PG4K Datasheet - Page 4

no-image

19C500PG4K

Manufacturer Part Number
19C500PG4K
Description
Industrial Pressure Sensors 0-500 Psi 1/8-27NPT 10 VDC
Manufacturer
Honeywell
Datasheet

Specifications of 19C500PG4K

Operating Pressure
0 psi to 500 psi
Pressure Type
Gauge
Accuracy
+/- 0.25 %
Output Type
Basic
Mounting Style
Stud
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
15 V
Port Size
1/8 in - 27 NPT
Pressure Port
Y
Sensor Type
Transducers
Body Style
Cylindrical
Function
Pressure
Primary Type
Pressure
Range, Measurement
500 PSI
Sensing Mode
Gage
Technology
Piezoelectric
Voltage, Supply
15 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
19 mm Series
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. The error band resulting from a maximum deviation of a transducer’s output parameter (offset, span, or resistance) as
PHYSICAL DIMENSIONS (For reference only: mm [in].)
Package 1 (see note): Cell Package
Note: Non-concentricity effects at the diaphragm weld area may cause runout of up to ±0.006 in between the upper and lower portions of the
sensor body. (It is recommended to use a counter bore to mate with this device to allow for this non-concentricity).
Package 2: Flush Mount Package
Package 3: Flush Mount with Flange
4 Honeywell • Sensing and Control
Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; 19C Supply VS = 10 Vdc ±0.01 Vdc or
IS = 1.5 mA ±0.0015 mA; 19U Supply VS = 5 Vdc ±0.01 Vdc or I = 1.0 mA ±0.0015 mA.
Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operation pressure range for increasing and decreasing pressure.
Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
Long-term stability over a six-month period.
Response time for a 0 psi to FSS pressure step change, 10% to 90% rise time.
The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact factory.
temperature is varied 25 °C [77 °F] to any other temperature within the specified range (0 °C to 82 °C [32 °F to 180 °F]). This
parameter is not 100% tested and is guaranteed by process design and tested on a sample basis only. Temperature
coefficient of span is evaluated using a 1 mA constant current excitation source.

Related parts for 19C500PG4K