3455RC 01000230 Honeywell, 3455RC 01000230 Datasheet

no-image

3455RC 01000230

Manufacturer Part Number
3455RC 01000230
Description
Industrial Temperature Sensors 1/2(L160:170/143:127
Manufacturer
Honeywell
Datasheets

Specifications of 3455RC 01000230

Function
Opens on Rise
Temperature Range
0 C to + 260 C
Supply Voltage
120 VAC to 250 VAC
Product
Temperature Sensors
Brand/series
3455RC
Current Rating
15 A
Mounting Type
Bracket
Output
SPST
Primary Type
Thermostat
Range, Measurement
260 °C
Standards
UL Listed and CSA Certified
Technology
Thermal Conductive
Temperature, Operating, Maximum
288 °C
Temperature, Operating, Minimum
-18 °C
Thermostat Type
Standard
Voltage, Supply
240 VAC
Electrical Rating
15 A @ 120 VAC, 10 A @ 240/277 VAC
Circuitry
SPST
Closure And Brackets
Stainless Steel/AluminumApplications
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Commercial
Thermostats
DESCRIPTION
Thermostats can provide either temperature control or over-
temperature protection by breaking electrical contact when a
specified temperature is reached.
Honeywell manufactures a wide range of 12,7 mm [0.5 in]
commercial snap-action thermostats for possible use in a wide
array of small and major appliances, office copy machines,
medical equipment, heat detectors, HVAC equipment and
more.
TABLE OF CONTENTS
DESCRIPTION
NOMENCLATURE
DEFINITION OF TERMS
NOTES
COMMERCIAL THERMOSTATS
REDI-TEMP THERMOSTATS
MOUNTING HARDWARE
2450R/2450HR/2455R/2452R/2452HR Series Phenolic Automatic Reset
2450RC/2450RCH/2455RC Series Ceramic Automatic Reset
2455RM/2450CM Series Phenolic or Ceramic Manual Reset
2455RD Series Phenolic Manual Reset
2455RBV Series Overmolded Automatic Reset
2450A/2455RA Series Heat Detection
2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot”
3455RC Series
Brackets
Brass mounting studs
Terminals
These snap-action thermostats include automatic and manual
reset options, phenolic or ceramic housings and a wide variety
of mounting brackets and terminal options.
Each thermostat's design is configured from a base unit, and
may be customized for temperature tolerance and mechanical
configurations, meeting the customer’s needs for accuracy and
exactitude.
Honeywell can also integrate these thermostats in higher value
cable assemblies, incorporating wire harness and connectors.
p. 1
p. 2
p. 3
p. 3
p. 4
p. 6
p. 9
p. 11
p. 13
p. 15
p. 17
p. 19
p. 20
p. 21
p. 22

Related parts for 3455RC 01000230

3455RC 01000230 Summary of contents

Page 1

... Thermostats can provide either temperature control or over- temperature protection by breaking electrical contact when a specified temperature is reached. Honeywell manufactures a wide range of 12,7 mm [0.5 in] commercial snap-action thermostats for possible use in a wide array of small and major appliances, office copy machines, medical equipment, heat detectors, HVAC equipment and more ...

Page 2

... Commercial Thermostats NOMENCLATURE The nomenclature given in Figure 1 is provided for reference only. Figure 1. Commercial Thermostat Nomenclature 2 www.honeywell.com/sensing ...

Page 3

... UL and CSA Approvals: 12,7 mm [0.5 in] thermostats are available with multiple agency approval for incorporation into equipment. • Fan control applications: Require thermostat set points to be derated by 20 °C from the equivalent temperature limit application. They also close on rise. • Dimensions: Are for reference only and are given in mm [in [120 F]). Honeywell Sensing and Control 3 ...

Page 4

... All versions are UL/CSA approved. The 2452R/2452HR/2455R version meets the requirements of EN60730-01. Potential applications include: • Power supplies • Appliances • ...

Page 5

... Note: 2450 approval rating is limited by EN60730-1 to 125 Vac max. Table 4. 2455R Contact Ratings Life Cycles 100,000 6,000 Note: Additional contact ratings are available, please contact Honeywell. Figure 3. 2450R/2450HR/2455R/2452R/2452HR Basic Dimensions 2450R 2452R 120 Vac 240 Vac 15 A resistive 10 A resistive ...

Page 6

... All versions are UL/CSA and European approved. Potential applications include high temperature control for: • Power supplies • Appliances • Medical equipment • Water heaters • ...

Page 7

... Standard Mean Differential °C [° [81 to 100 [ [ [ [ [ [ [ [ [ [91 to 100 [ [ [91 to 100 [ [ [60 to 100 [50 to 90] Honeywell Sensing and Control 7 ...

Page 8

... Table 8. 2450RCH/2450RC Contact Ratings Life Cycles 100,000 30,000 Table 9. 2455RC Contact Ratings Life Cycles 100,000 100,000 100,000 Note: Additional contact ratings are available, please contact Honeywell. Figure 5. 2450RC/2450RCH/2455RC Basic Dimensions 2450RC 8 www.honeywell.com/sensing 120 Vac 15 A resistive 125 VA pilot duty 120 Vac 15 A resistive 4 ...

Page 9

... Medical equipment • Water heaters • Office automation • Industrial equipment • HVAC equipment Tolerance °C [°F] ±5 [±8] ±6 [±10] ±7 [±12] Tolerance °C [°F] ±5 [±8] ±6 [±10] ±7 [±12] ±8 [±15] ±10 [±18] ±11 [±20] Honeywell Sensing and Control 9 ...

Page 10

... Reset pin operation should not be performed above 70% of set point temperature. Table 13. 2450CM/2455RM Contact Ratings Life Cycles 6,000 6,000 Note: Additional contact ratings are available, please consult Honeywell. Figure 7. 2455RM/2455CM Basic Dimensions 2455RM A Maximum travel of reset button on contact opening B On contact closing ...

Page 11

... Potential applications include those where a manual reset is desired, including: • Power supplies • Appliances • Medical equipment • Water heaters • Office automation • Industrial equipment • HVAC equipment Tolerance °C [°F] ±5 [±8] ±6 [±10] ±7 [±12] Honeywell Sensing and Control 11 ...

Page 12

... Base Contacts Terminals Closure Brackets Approvals Table 16. 2455RD Contact Ratings Life Cycles 6000 Note: Additional contact ratings are available, please consult Honeywell. Figure 9. 2455RD Basic Dimensions A Maximum travel of reset button on contact opening B On contact closing C Reset button 12 www.honeywell.com/sensing Parameter SPST manual 15 A resistive at 6,000 cycles (UL) ...

Page 13

... Close °C [°F] °C [°F] ±4 [±7] ±6 [±10] ±3 [±6] ±4 [±8] ±3 [±5] ±4 [±8] ±3 [±6] ±6 [±10] ±3 [±5] ±4 [±8] Standard Mean Differential °C [° [ [ [ [ [20 to 50] Honeywell Sensing and Control 13 ...

Page 14

... Terminals Closure Brackets Approvals Weight Table 19. 2455RBV Series Contact Ratings Life Cycles 100,000 6,000 100,000 Note: Additional contact ratings are available, please contact Honeywell. Figure 11. 2455RBV Basic Dimensions A Specify wire gauge and insulation B Specify dimension 14 www.honeywell.com/sensing Parameter SPST automatic see Table 19 120 Vac to 250 Vac 0 ° ...

Page 15

... Notes: • Additional switches can be provided as long as they fall between 47,2 °C to 107,2 °C [117 °F to 225 °F] close on rise or open or rise. • Please consult Honeywell for tolerances and temperatures not listed. All versions are UL approved. Potential applications: • Smoke alarm/heat detectors in industrial, residential and commercial ° ...

Page 16

... Terminals Closure Brackets Approvals Weight Figure 13. 2450A/2455RA Basic Dimensions 2450A Figure 14. 2450A/2455RA Collector B247 16 www.honeywell.com/sensing Parameter SPST automatic 3 A 120 Vac 47,2 °C to 107,2 °C [117 °F to 225 °F] -0 °C to 150 °C [32 °F to 302 °F] phenolic gold flash unplated brass, plated brass ...

Page 17

... All versions are UL/CSA approved and European approved. Potential applications include: • Power supplies • Appliances • Medical equipment • Water heaters • Office automation • Industrial equipment • HVAC equipment Tolerance °C [°F] 5 [8] 6 [10] 7 [12] 8 [15] 10 [18] 11 [20] 14 [25] Honeywell Sensing and Control 17 ...

Page 18

... Table 24. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” Contact Ratings Cycles 1 Notes: • Resets below -35 °C [-31 °F]. • Additional contact ratings are available. Please consult Honeywell. Figure 17. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series “One Shot” Basic Dimension 2450R/22450RC “One Shot” 2450HR “One Shot” 18 www.honeywell.com/sensing Parameter ...

Page 19

... Honeywell Sensing and Control Open Tolerance °C [°F] ±3 [±5] ±3 [±5] ±3 [±5] ±3 [±5] ±3 [±5] ±3 [±5] ±3 [±5] ±4 [±6] ± ...

Page 20

... Commercial Thermostats MOUNTING HARDWARE Figure 19. Brackets B-201, B-201A, B-201B Stationary Surface B-203S B-209 B-213 20 www.honeywell.com/sensing B-203, B-203A, B-203B Movable Surface B-206 B-210 8,71 R [0.343] 12,70 [0.500] 2X 3,73 DIA 11,10 [0.147] [0.437] 3,18 [0.125] B-230 B-205, B-205A Air Stream A Enclosed B Exposed B-207 3,96 [0 ...

Page 21

... B-221: 8-32 B-222: 10-24 B-223: 10-32 B-224: M3X0.5 B-225: M4X0.7 B-226: M5X0.8 B-227: M6X1.0 A Undercut to minor diameter B-327 B-249 B240 6-32 8-32 10-32 M3X0.5 M4X0.7 M5X0.8 B Specify length B-901 4,1 5,0 [0.062] [0.17 0.7 B-250 C Specify thread B-902 Honeywell Sensing and Control 21 ...

Page 22

... DIA [0.067] 27,59 [1.086] 45° 6,16 [0.242] T-161 T-162 T-168 T-169 22 www.honeywell.com/sensing T-106 T-107 Vertical Solder Inside Vertical Solder Outside T-146 T-147 1/4 in Quick Connect, Horizontal 1/4 in Quick Connect, Vertical 1,70 DIA [0.067] T-150 T-151 3/16 in Quick Connect. Vertical 3/16 in Quick Connect, 45° ...

Page 23

... Quick Connect, Flat Horizontal terminal thickness = 0.8 mm [0.032 in] 32,5 [1.28 threaded for M3 screw T-806 Vertical Weld Inside 2,54 12,90 [0.100] [0.508] T-850 3/16 in Quick Connect, Vertical terminal thickness = 0.8 mm [0.032 in] T-807 Vertical Weld Outside T-899 8,7 4,9 [0.34] [0.19] Honeywell Sensing and Control 23 ...

Page 24

... In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing ...

Related keywords