3455RC 01000234 Honeywell, 3455RC 01000234 Datasheet - Page 15

no-image

3455RC 01000234

Manufacturer Part Number
3455RC 01000234
Description
Industrial Temperature Sensors 1/2(L199:211/183:167
Manufacturer
Honeywell
Datasheets

Specifications of 3455RC 01000234

Function
Opens on Rise
Temperature Range
0 C to + 260 C
Supply Voltage
120 VAC to 250 VAC
Product
Temperature Sensors
Brand/series
3455RC Series
Mounting Type
Bracket
Primary Type
Temperature
Standards
UL, CSA, VDE
Voltage, Supply
120/240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 12. 2450A/2455RA Heat Detection Thermostats
Table 20. 2450A/2455RA Series Standard Temperature Characteristics
Notes:
• Additional switches can be provided as long as they fall between 47,2 °C to 107,2 °C [117 °F to 225 °F] close on rise or open or
• Please consult Honeywell for tolerances and temperatures not listed.
The 2450A/2455RA Series is a single pole, single throw,
snap-acting, non-adjustable thermostat designed for easy
mounting in devices such as fire alarms, security devices
and smoke detectors. A temperature-sensitive bimetal disc,
electrically and thermally isolated from the switch, is used to
actuate the normally-closed contacts. Contacts open when
surface or ambient temperatures increase to the operating
set point of the calibrated bimetal disc. Devices are UL
recognized and designed for use in both photoelectric and
ionization type smoke detectors. Thermostats are available
with and without collectors and meet UL spacing
requirements for 15 ft, 30 ft and 50 ft. They are available to
open or close on a temperature rise of 47
107
voltage requirements and are epoxy sealed at the cap and
terminal for long storage life of the application. Collectors
are available in silver, black, beige, gold or bronze finishes.
NOTICE
Final approval of a fire detection system is determined by UL as outlined in UL #521 and UL #217 for the suitability of the
combination of the thermostat (2450A/2455RA) and the user’s mounting base, together with its intended application of the total
fire detection system. To assist the use with design and testing , a minimum of 0.25 in extension beyond the housing is
recommended.
rise.
°
C [225
107 ±4 [225 ±7]
57 ±3 [135 ±5]
69 ±3 [156 ±5]
85 ±4 [185 ±7]
47 ±3 [117±5]
°C [°F]
Close
°
F]. Devices feature gold contacts for low
Detection (Close on Rise)
30 min [85 min]
32 min [90 min]
32 min [90 min]
32 min [90 min]
32 min [90 min]
°
C [117
°C [°F]
Open
°
F] to
All versions are UL approved.
Potential applications:
• Smoke alarm/heat detectors in industrial, residential and
commercial
107 ±4 [225 ±7}
57 ±3 [117 ±5]
57 ±3 [135 ±5]
69 ±3 [156 ±5]
85 ±4 [185 ±7]
°C [°F]
Open
Release (Open on Rise)
Honeywell Sensing and Control
30 min [85 min]
32 min [90 min]
32 min [90 min]
32 min [90 min]
32 min [90 min]
°C [°F]
Close
15