3455RC 01000233 Honeywell, 3455RC 01000233 Datasheet - Page 9

no-image

3455RC 01000233

Manufacturer Part Number
3455RC 01000233
Description
Industrial Temperature Sensors 0 C to + 260 C Temperature Sensors
Manufacturer
Honeywell
Datasheet

Specifications of 3455RC 01000233

Function
Opens on Rise
Temperature Range
0 C to + 260 C
Supply Voltage
120 VAC to 250 VAC
Product
Temperature Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 6. 2455RM/2450CM Series Phenolic or Ceramic Manual Reset Thermostats
Table 10. 2455RM Series Standard Temperature Characteristics
Table 11. 2450CM Series Standard Temperature Characteristics
The 2455RM (phenolic)/2450CM (ceramic) Series is a
single pole, single throw, snap-acting, non-adjustable
thermostat. A temperature-sensitive bimetal disc, electrically
and thermally isolated from the switch, is used to actuate
the normally-closed contacts. Contacts open when surface
or ambient temperatures increase to the operating set point
of the calibrated bimetal disc. The entire switch is enclosed
in a housing; the bimetal disc is retained by a metal heat-
conducting end cap. The circuit remains open above the
room ambient temperature until the manual reset button is
depressed. Due to the small size of this unit and the
inherently low mass of the bimetal snap-action disc,
response of this thermostat to temperature changes is
extremely rapid, compared to other commercially available
thermostatic devices. For increased sensitivity, an exposed
bimetal disc may be specified. A variety of mounting
brackets and terminals is available.
122 °C to 150 °C [251 °F to 302 °F]
122 °C to 149 °C [251 °F to 300 °F]
150 °C to 177 °C [301 °F to 350 °F]
177 °C to 204 °C [351 °F to 400 °F]
205 °C to 232 °C [401 °F to 450 °F]
94 °C to 121 °C [201 °F to 250 °F]
94 °C to 121 °C [201 °F to 250 °F]
52 °C to 93 °C [125 °F to 200 °F]
52 °C to 93 °C [125 °F to 200 °F]
Operating Temperature Range
Operating Temperature Range
All versions are UL/CSA, European approved.
Potential applications include those where a manual reset is
desired, including:
• Power supplies
• Appliances
• Medical equipment
• Water heaters
• Office automation
• Industrial equipment
• HVAC equipment
Tolerance °C [°F]
Tolerance °C [°F]
±10 [±18]
±11 [±20]
±6 [±10]
±7 [±12]
±6 [±10]
±7 [±12]
±8 [±15]
±5 [±8]
±5 [±8]
Honeywell Sensing and Control
9