BWR-12/125-D12-C Murata Power Solutions Inc, BWR-12/125-D12-C Datasheet - Page 3

DC/DC Converters & Regulators 3W 12V/+-12V +-125mA

BWR-12/125-D12-C

Manufacturer Part Number
BWR-12/125-D12-C
Description
DC/DC Converters & Regulators 3W 12V/+-12V +-125mA
Manufacturer
Murata Power Solutions Inc
Series
BWRr
Datasheet

Specifications of BWR-12/125-D12-C

Output Power
2 W
Input Voltage Range
9 V to 18 V
Input Voltage (nominal)
12 V
Number Of Outputs
2
Output Voltage (channel 1)
+/- 12 V
Output Current (channel 1)
+/- 125 mA
Output Voltage (channel 2)
12 V
Output Current (channel 2)
+/- 125 mA
Isolation Voltage
1 KV
Package / Case Size
DIP
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
BWR-12/125-D12-C
Performance/Functional Specifications
Typical @ T
Dimensions
Input Voltage Range:
Input Current
Input Filter Type
Reverse-Polarity Protection
V
Temperature Coefficient
Ripple/Noise (20MHz BW)
Line/Load Regulation
Efficiency
Isolation Voltage
Current Limiting:
Transient Response (50% load step)
Switching Frequency:
Operating Temperature
Storage Temperature
Case Material
Pin Material
Weight
These power converters require a minimum 10% loading to maintain specified regulation.
Operation under no-load conditions will not damage these devices; however they may not
meet all listed specifications.
Application-specific internal input/output filtering can be recommended and perhaps added
internally upon request. Contact DATEL Applications Engineering for details.
Devices can be screened or modified for higher guaranteed isolation voltages.
Contact DATEL Applications Engineering for details.
Devices can be warranted or screened for lower-temperature operation.
Contact DATEL Applications Engineering for details. See DATEL's new BST 3W Models
for guaranteed operation to –40°C.
OUT
"D5" Models
"D12" Models
"D48" Models
"D5" Models
"D12" and "D48" Models
"D5" Models
"D12" and "D48" Models
(Ambient, no derating)
Accuracy (50% load)
A
= +25°C under nominal line voltage and full-load conditions unless noted.
Dynamic Characteristics
Environmental
Physical
Output
Input
4.5-9 Volts (5V nominal)
9-18 Volts (12V nominal)
18-72 Volts (48V nominal)
See Ordering Guide
Pi
Yes (Instantaneous, 2A maximum)
±1%, maximum
±0.02% per °C
See Ordering Guide
See Ordering Guide
See Ordering Guide
1000Vdc, minimum
Power-limiting technique, auto-recovery
Hiccup technique, auto-recovery
200μsec to ±1% of final value
200kHz
170kHz
–25 to +75°C
–40 to +100°C
Diallyl phthalate, UL94V-0-rated
RoHS: Gold plate over copper alloy
Non RoHS: Tin plate over copper alloy
0.5 ounces (14.2 grams)
1.25" x 0.8" x 0.45" (31.8 x 20.3 x 11.4mm)
www.murata-ps.com
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "floating." Any
BWR model may be configured to produce an output of 10V, 24V or 30V
(for ±5V, ±12V or ±15V models, respectively) by applying the load across
the +Output and –Output pins (pins 6 and 8), with either output grounded.
The Common (pins 5 and 7) should be left open. Minimum 20% loading is
recommended under these conditions.
Filtering and Noise Reduction
All BWR 3 Watt DC/DC Converters achieve their rated ripple and noise
specifications without the use of external input/output capacitors. In critical
applications, input/output ripple and noise may be further reduced by install-
ing electrolytic capacitors across the input terminals and/or low-ESR tanta-
lum or electrolytic capacitors across the output terminals. Output capacitors
should be connected between their respective output pin (pin 6 or 8) and
Common (pins 5 and 7) as shown in Figure 2. The caps should be located
as close to the power converters as possible. Typical values are listed in the
tables below. In many applications, using values greater than those listed
will yield better results.
In critical, space-sensitive applications, DATEL may be able to tailor the inter-
nal input/output filtering of these units to meet your specific requirements.
Contact our Applications Engineering Group for additional details.
Input Voltage:
Input Reverse-Polarity Protection
Output Overvoltage Protection
Output Current
models
sustained output short
Storage Temperature
Lead Temperature (soldering, 10 sec.)
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied.
T E C H N I C A L N O T E S
To Reduce Input Ripple
To Reduce Output Ripple
"D5" Models
"D12" Models
"D48" Models
"D5" Models
"D12" Models
"D48" Models
±5V Outputs
±12/15V Outputs
Technical enquiries email: sales@murata-ps.com, tel:
Absolute Maximum Ratings
3 Watt, Dual Output DC/DC Converters
47μF, 15V
10μF, 35V
4.7μF, 100V
47μF, 10V, Low ESR
22μF, 20V, Low ESR
12 Volts
20 Volts
80 Volts
Current must be <2A. Brief duration
only. Fusing recommended.
None
Current limited. Max. current and
short-circuit duration are model
–40 to +100°C
+300°C
BWR Series
dependent. "D12" and "D48"
MDC_BWR3W.B01 Page 3 of 4
can withstand
circuits.