DC/DC Converters & Regulators 15W 5V to 12V 1.25A

UWR-12/1250-D5A-C

Manufacturer Part Number
UWR-12/1250-D5A-C
Description
DC/DC Converters & Regulators 15W 5V to 12V 1.25A
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of UWR-12/1250-D5A-C

Output Power
15 W
Input Voltage Range
4.7 V to 7.5 V
Input Voltage (nominal)
5 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
1.25 A
Isolation Voltage
1.5 KV
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
UWR-12/1250-D5A-C
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Design for Reliability
Design for Reliability is woven throughout our multi-phased, new-product-
development process. Design-for-reliability practices are fully documented
and begin early in the new-product development cycle with the following
goals:
1. To work from an approved components/vendors list ensuring the use of
reliable components and the rigorous qualifi cation of new components.
2. To design with safety margins by adhering to a strict set of derating
guidelines and performing theoretical worst-case analyses.
3. To locate potential design weaknesses early in the product-development
cycle by using extensive HALT (Highly Accelerated Life Testing).
4. To prove that early design improvements are effective by employing a
thorough FRACA (Failure Reporting Analysis and Corrective Action)
system.
HALT Testing
The goal of the accelerated-stress techniques used by DATEL is to force
device maturity, in a short period of time, by exposing devices to excessive
levels of "every stimulus of potential value." We use HALT (Highly Acceler-
ated Life Testing) repeatedly during the design and early manufacturing
phases to detect potential electrical and mechanical design weaknesses
that could result in possible future fi eld failures.
During HALT, prototype and pre-production DC/DC converters are sub-
jected to progressively higher stress levels induced by thermal cycling,
rate of temperature change, vibration, power cycling, product-specifi c
stresses (such as dc voltage variation) and combined environments. The
stresses are not meant to simulate fi eld environments but to expose any
weaknesses in a product’s electro/mechanical design and/or assembly
processes. The goal of HALT is to make products fail so that device weak-
nesses can be analyzed and strengthened as appropriate. Applied stresses
are continually stepped up until products eventually fail. After corrective
actions and/or design changes, stresses are stepped up again and the cycle
is repeated until the "fundamental limit of the technology" is determined.
100
–20
–40
80
60
40
20
0
10
20
30
Typical HALT Profi le
40
Test Time (minutes)
50
60
70
www.murata-ps.com/locations
Single Output, High Reliability, 2" x 2", 14-20 Watt, DC/DC Converters
80
90
40
20
0
In-Line Process Controls and Screening
A combination of statistical sampling and 100% inspection techniques
keeps our assembly line under constant control. Parameters such as
solder-paste thickness, component placement, cleanliness, etc. are statisti-
cally sampled, charted and fi ne tuned as necessary. Visual inspections are
performed by trained operators after pick-and-place, soldering and cleaning
operations. Units are 100% electrically tested prior to potting. All devices
are temperature cycled, burned-in, hi-pot tested and fi nal-electrical tested
prior to external visual examination, packing and shipping.
Rapid Response to Problems
DATEL employs an outstanding corrective-action system to immediately
address any detected shortcomings in either products or processes. When-
ever our assembly, quality or engineering personnel spot a product/process
problem, or if a product is returned with a potential defect, we immediately
perform a detailed failure analysis and, if necessary, undertake corrective
actions. Over time, this system has helped refi ne our assembly operation to
yield one of the lowest product defect rates in the industry.
DATEL has invested in a Qualmark OVS-1 HALT tester capable of applying
voltage and temperature extremes as well as 6-axis, linear and rota-
tional, random vibration. A typical HALT profi le (shown above) consists of
thermal cycling (–55 to +125°C, 30°C/minute) and simultaneous, gradually
increasing, random longitudinal and rotational vibration up to 20G’s with
load cycling and applied-voltage extremes added as desired. Many devices
in DATEL’s new A-Series could not be made to fail prior to reaching either
the limits of the HALT chamber or some previously known physical limit of
the device. We also use the HALT chamber and its ability to rapidly cool
devices to verify their "cold-start" capabilities.
Qualifi cation
For each new product, electrical performance is verifi ed via a comprehensive
characterization process and long-term reliability is confi rmed via a rigorous
qualifi cation procedure. The qual procedure includes such strenuous tests as
thermal shock and 500 hour life. Qual testing is summarized below.
Qualifi cation Test
HALT
High Temperature Storage
Thermal Shock
Temperature/Humidity
Lead Integrity
Life Test
Marking Permanency
End Point Electrical Tests
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without
notice.
* Interim electrical test at 200 hours.
Qualifi cation Testing
09/01/09 MDC_UWR14-20 Series.B04 Page 6 of 6
Method/Comments
DATEL in-house procedure
Max. rated temp., 1,000 hours
10 cycles, –55 to +125°C
+85°C, 85% humidity, 48 hours
DATEL in-house procedure
+70°C, 500 hours*
DATEL in-house procedure
Per product specifi cation
UWR Series