OBQ24SC0512 ETA-USA, OBQ24SC0512 Datasheet - Page 8

no-image

OBQ24SC0512

Manufacturer Part Number
OBQ24SC0512
Description
DC/DC Converters & Regulators 3W 4.5-16V TO 24V
Manufacturer
ETA-USA
Series
OBQr
Datasheet

Specifications of OBQ24SC0512

Output Power
3 W
Input Voltage Range
4.5 V to 16 V
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
0.13 A
Isolation Voltage
500 V
Package / Case Size
SIP
Output Voltage
24 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
b.Dynamic Line Regulation +/-[mV](maximum) *4
Specifications
Output Voltage [V]
Output Current [A]
Voltage Tolerance +/-[mV](maximum) *2
Ripple and Noise [mVp-p](maximum) *3
Regulation
a.Static Line Regulation [mV](maximum)
c.Static Load Regulation [mV](maximum) *5
d.Temperature Coefficient *8
e.Drift[mV](maximum) *9
f.Dynamic Load Regulation [mV](maximum) *10
g.Recovery Time *4, *10
Rise up time
Hold up time
Functions
Overcurrent Protection
Overvoltage Protection
Remote Sence
Trimming of output voltage[mV] (typical) *11
Input Fuse
Environmental
Operating Temperature
(derating)
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Isolation Resistance
Capacitance(input-output) [pF](typical)
Vibration
Shock
Cooling
Weight (typical)
Conditions:
*1 at 25 ℃ and rated input/output
*2 OBQ**WC0512 satisties the above-mentioned specifications at the same load conditions on both outputs
*3 measured by a bayonet probe at the output connector at a 0 to 100Mhz bandwidth
*4 when input voltage changed from 8V to 32V rapidly at rated output
*5 when output current changed from 0mA to rated current keeping the current of other output below minimum rated current
*6 when output current changed from minimum rated current to rated current keeping the current of other output
*7 when output current of both outputs changed from 0mA to rated current identically at rated input
*8 at -20 to +71 ℃
*9 for 7hour period after 1hour warm-up at 25 ℃ and rated input/output
*10 when output current changed rapidly between 25% and 75% of rated current at rated input
*11 to increase output voltage,put a resistor between pin"0" and trimming pin
*12 to reduce output voltage,put a resistor between pin"+" and trimming pin
*13 operating temperature of OBQ**WC1224 should be ≦ 71-2*(Ein-24) at input voltage from 24V to 32V
at rated input
above minimum rated current at rated input
3WATTS/SINGLE/2 OUTPUT
*13
OBQ**SC/WC1224
[mV](maximum)
[mV](typical) *12
[mV](maximum)
*7
*6
OBQ05SC1224 OBQ12SC1224 OBQ15SC1224 OBQ24SC1224 OBQ22WC1224
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
+250
-250
0.5
100
200
150
25
25
40
5
Foldback/Current Limiting with automatic recovery at discontinuos short circuit conditions
SC/WC1224 Output Specifications
Primary-Secondary
0.25
+250
-900
240
200
360
12
60
60
75
3.5%/(50 ℃ to 71 ℃ ) (out of warranty ≧ 71 ℃ )
Primary-Secondary
10mS(typical) at rated input/output
20 to 90%/RH(non-condensing)
20-90%/RH(non-condensing)
-1600
0.20
+350
300
200
250
15
75
75
90
50MΩ(minimum) by DC500V insulation tester
0.03%/ ℃ (maximum)
open board type:6g
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
20mS(typical)
Not specified
Not available
Not available
-20 to +85 ℃
-20 to 71 ℃
Convection
Installed
294m/s
Model
2200
100
AC500V for 1minute
-4000
0.13
+650
2
480
120
200
120
135
500
24
(Ein=Input Voltage)
±1000
±480
+12
240
300
±60
300
60
75
0.013-0.13
±1000
±480
240
300
±60
300
-12
60
75
±1200
OBQ23WC1224
±600
+15
300
300
±75
300
75
90
0.010-0.10
±1200
±600
300
300
±75
300
-15
75
90

Related parts for OBQ24SC0512