GLC50AG SL Power, GLC50AG Datasheet

Linear & Switching Power Supplies 50W +5.05V/+12V/-12V

GLC50AG

Manufacturer Part Number
GLC50AG
Description
Linear & Switching Power Supplies 50W +5.05V/+12V/-12V
Manufacturer
SL Power
Series
GLCr
Type
Switchingr
Datasheet

Specifications of GLC50AG

Product
Switching
Commercial/medical
Commercial
Output Power Rating
20 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
3
Output Voltage (channel 1)
5.05 V
Output Current (channel 1)
4 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
2.5 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
0.2 A
Mounting Style
Chassis
Open Frame/enclosed
Open Frame
Output Type
Triple Output
Output Voltage
5.05|12|-12 V
Maximum Current Rating
1.5 A
Maximum Output Current
4|2.5|0.2 A
Maximum Output Power
50 W
Efficiency
85 %
Input Frequency
47 to 63 Hz
Operating Temperature
0 to 50 °C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
GLC50A-G
• Cost-effective power source
• Universal input 90-264 Vac
• 2-year warranty
• Compact (4.25” x 2.50” x 1.25”; meets
• Overload and overvoltage protection
• Conducted EMI exceeds FCC Class B and
• Commercial UL/CSA/IEC60950-1, EN60950 approvals
• Medical UL/EN/IEC60601-1, CSA22.2 No. 601,
• RoHS compliant models available (G suffix)
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase..
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.5 A
Hold-Up Time
15 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Output Regulation
To maintain specified regulation on multi-output models, output #1 load
power must be at least 1/5th of, and not greater than 5 times output #2 load
power.
Overload Protection
Fully protected against short circuit and output overload. Short circuit pro-
tection is cycling type power limit on outputs 1 & 2; foldback type on output
3. Recovery after fault is automatic. See output ratings chart for additional
notes or conditions.
Efficiency
70-85% at full rated load, nominal input voltage, depending on model and
load distribution.
Minimum Load
Operating without minimum load will not degrade reliability, but regula-
tion may be affected. Multiple output models require 20% minimum load
on V1 for proper regulation. Single models require 5% minimum load when
a transient load greater than 30% is applied or removed, but will operate
without load.
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic failure oc-
curs in the unit—fuse does not blow on overload or short circuit.
Inrush is limited by internal thermistors. Inrush at 240 Vac,
averaged over the first ac half-cycle under cold start
conditions will not exceed 37 A.
GLOBAL PERFORMANCE SWITCHERS
Features:
All specifications are typical at nominal input, full load at 25
1U applications)
CISPR 22 Class B (Commercial models) and
CISPR 11 Class B (Medical models)
marked to LVD
GLC50 Commercial/GLM50 Medical
O
C unless otherwise stated
50 WATT GLOBAL PERFORMANCE SWITCHERS
Temperature Coefficient
0.03%/°C typical on all outputs.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise
probe directly across output terminals of the power supply.
Transient Response
500 μs typical response time for return to within 0.5% of final value for a 50% load
step change. ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shut-
down overshoot less than 3%.
Voltage Adjustment
Built-in potentiometer adjusts V1 ±5%.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions require-
ments:
EMI SPECIFICATIONS
Conducted Emissions GLC
Conducted Emissions GLM
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Commercial Leakage Current
160 μA 254 Vac @ 60 Hz input (with no deviations).
Commercial Safety
All GLC models are approved to UL1950, CSA22.2 No.
234 Level 3, IEC950 and EN60950.
Medical Leakage Current
100 μA 264 Vac @ 60 Hz input (normal conditions).
Medical Safety
All GLM50 models are approved to UL/EN/IEC60601-1, CSA22.2 No. 601.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
D C P o w e r S u p p l i e s

Related parts for GLC50AG

GLC50AG Summary of contents

Page 1

GLOBAL PERFORMANCE SWITCHERS Features: • Cost-effective power source • Universal input 90-264 Vac • 2-year warranty • Compact (4.25” x 2.50” x 1.25”; meets 1U applications) • Overload and overvoltage protection • Conducted EMI exceeds FCC Class B and CISPR ...

Page 2

... SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07. Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. ...

Related keywords