GSM15-5G SL Power, GSM15-5G Datasheet - Page 2

Linear & Switching Power Supplies 15W 5.1V 2.35A

GSM15-5G

Manufacturer Part Number
GSM15-5G
Description
Linear & Switching Power Supplies 15W 5.1V 2.35A
Manufacturer
SL Power
Series
GSMr
Datasheet

Specifications of GSM15-5G

Product
Switching
Commercial/medical
Medical
Output Power Rating
12 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
5.1 V
Output Current (channel 1)
2.35 A
Mounting Style
Chassis
Open Frame/enclosed
Open Frame
Output Type
Single Output
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
GSM15-5-G
Notes:
A. Rating with unrestricted convection cooling.
B. Peak Power for 60 sec. 10% duty cycle or continuous rating with 150 LFM of airflow.
C. Output voltages preset at factory, not user adjustable.
D. Add “G” suffix to model nuber for RoHS compliant model.
SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 1/07.
Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
GSM15 MECHANICAL SPECIFICATIONS
Medical
Model
GSM15-5
GSM15-12
GSM15-15
GSM15-24
GSM15-28
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
INPUT: J1 AMP P/N 640456-4
PIN 1) AC LINE
PIN 2) N/C
PIN 3) N/C
PIN 4) AC NEUTRAL
GND: 0.098 DIA. THRU HOLE
OUTPUT: J2 AMP P/N 640456-4
PIN 1) COMMON Return
PIN 2) COMMON Return
PIN 3) OUTPUT #1 + Vout
PIN 4) OUTPUT#1 +Vout
MATING CONNECTOR AMP P/N
MTA – 100 Recepticle
NOTE: 3A MAXIMUM RECOMMENDED
CURRENT PER CONNECTOR PIN
Voltage
Output
5.1 V
12 V
15 V
24 V
28 V
OPERATING
0 to 50° C
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
Min.
0 A
0 A
0 A
0 A
0 A
pk
rms’
0.003 g
2
/Hz
Normal (A)
0.625 A
2.35 A
1.25 A
0.54 A
1.0 A
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
0.026 g
2
/Hz
76.20mm x 53.34mm x 23.37mm
Peak (B)
0.75 A
0.64 A
1.5 A
1.2 A
Weight: 0.25 LBS. [.113 kg]
3 A
3.00 x 2.10 x .92 inches
Overall Dimensions:
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
MAX.
Initial Set
Point
2.5%
2.5%
2.5%
2.5%
2.5%
OVP Setpoint
280 V
7.2 V
16 V
21 V
32 V
Regulation
Total
2%
2%
2%
2%
2%
Ripple and
Noise
1%
1%
1%
1%
1%

Related parts for GSM15-5G