Linear & Switching Power Supplies 240W 24V 10A

DRP-240-24

Manufacturer Part NumberDRP-240-24
DescriptionLinear & Switching Power Supplies 240W 24V 10A
ManufacturerMean Well
DRP-240-24 datasheets
 

Specifications of DRP-240-24

ProductSwitchingCommercial/medicalCommercial
Output Power Rating240 WInput Voltage85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs1Output Voltage (channel 1)24 V
Output Current (channel 1)10 AMounting StyleDIN Rail
Output TypeDCPower Supply TypeSwitch Mode
Power Supply Output TypeFixedNo. Of Outputs1
Input Frequency63HzOutput Voltage24V
Output Current10APower Rating240W
Rohs CompliantYesLead Free Status / RoHS StatusLead free / RoHS Compliant
1
Page 1
2
Page 2
Page 1/2

Download datasheet (346Kb)Embed
Next
240W Single Output Industrial DIN RAIL Power Supply
SPECIFICATION
MODEL
DRP-240-24
DC VOLTAGE
24V
RATED CURRENT
10A
CURRENT RANGE
0 ~ 10A
RATED POWER
240W
RIPPLE & NOISE (max.)
80mVp-p
Note.2
OUTPUT
VOLTAGE ADJ. RANGE
24 ~ 28V
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
800ms, 40ms
HOLD UP TIME (Typ.)
24ms
VOLTAGE RANGE
85 ~ 264VAC
Note.5
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.96/230VAC
INPUT
EFFICIENCY (Typ.)
84%
AC CURRENT (Typ.)
2.8A/115VAC
INRUSH CURRENT (Typ.)
COLD START 27A/115VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
105 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
30 ~ 36V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
100
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +70
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL508,
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
SAFETY &
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
EMI CONDUCTION & RADIATION
Compliance to EN55011,EN55022 (CISPR22) Class B
(Note 4)
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
EMS IMMUNITY
MTBF
289.9Khrs min.
OTHERS
DIMENSION
125.5*125.2*100mm (W*H*D)
1.2Kg; 12pcs/15.5Kg/1.29CUFT
PACKING
NOTE
1.0%
0.5%
1.0%
/230VAC
8
00ms, 40ms
/115VAC at full load
/230VAC
24
ms
/115VAC at full load
120 ~ 370VDC
0.99/115VAC at full load
1.4A/230VAC
45A/230VAC
5
(TSW1)detect on heat sink of power transistor
(Refer to output load derating curve)
0.03%/
(0 ~ 50
UL60950-1,
TUV EN60950-1 approved
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
MIL-HDBK-217F (25 )
D R P - 2 4 0
DRP-240-48
48V
5A
0 ~ 5A
240W
150mVp-p
48 ~ 53V
1.0%
0.5%
1.0%
85%
54 ~ 60V
File Name:DRP-240-SPEC 2010-09-24
s e r i e s

DRP-240-24 Summary of contents

  • Page 1

    ... Single Output Industrial DIN RAIL Power Supply SPECIFICATION MODEL DRP-240-24 DC VOLTAGE 24V RATED CURRENT 10A CURRENT RANGE 0 ~ 10A RATED POWER 240W RIPPLE & NOISE (max.) 80mVp-p Note.2 OUTPUT VOLTAGE ADJ. RANGE 24 ~ 28V VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME 800ms, 40ms HOLD UP TIME (Typ ...

  • Page 2

    ... Pin No. Assignment AC/N 3 AC/L Terminal Pin Number Assignment (TB2) Pin No. Assignment 1,2 DC OUTPUT +V 3,4 DC OUTPUT -V fosc : 100KHz RECTIFIERS & FILTER CONSTANT CURRENT LIMITING & DETECTION CIRCUIT O.V.P. 100 110 135 155 230 INPUT VOLTAGE (V) 60Hz File Name:DRP-240-SPEC 2010-09- Unit: Ta=25 264 ...