MDR-60-5 Mean Well, MDR-60-5 Datasheet

Linear & Switching Power Supplies 50W 5V 10A

MDR-60-5

Manufacturer Part Number
MDR-60-5
Description
Linear & Switching Power Supplies 50W 5V 10A
Manufacturer
Mean Well
Datasheet

Specifications of MDR-60-5

Product
Switching
Commercial/medical
Commercial
Output Power Rating
50 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Output Current (channel 1)
10 A
Mounting Style
DIN Rail
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION DC OK SIGNAL
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
LEAKAGE CURRENT
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
INRUSH CURRENT (Typ.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
60W Single Output Industrial DIN Rail Power Supply
Note.3
Note.5
Note.2
5V
10A
0 ~ 10A
50W
80mVp-p
5 ~ 6V
500ms, 30ms/230VAC
50ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
MDR-60-5
1.8A/115VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6.25 ~ 7.25V
Protection type : Shut down o/p voltage, re-power on to recover
Relay contact rating(max.): 30V/1A resistive
-20 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
Component :
UL508, UL60950-1,
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
299.2K hrs min.
40*90*100mm (W*H*D)
0.33Kg; 42pcs/14.8Kg/0.82CUFT
78%
COLD START 30A/115VAC
<1mA / 240VAC
2.0%
1.0%
1.5%
0.03%/
(0 ~ 50
(Refer to output load derating curve)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min.
I/P-FG:1.5KVAC
120 ~ 370VDC
1A/230VAC
MIL-HDBK-217F (25 )
20ms/115VAC at full load
TUV EN60950-1 a
500ms, 30ms/115VAC at full load
12V
5A
0 ~ 5A
60W
120mVp-p
12 ~ 15V
MDR-60-12
15.6 ~ 18V
86%
60A/230VAC
1.0%
1.0%
1.0%
O/P-FG:0.5KVAC
pproved, NEC class 2 / LPS compliant (24V,48V only)
each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
24V
2.5A
0 ~ 2.5A
60W
150mVp-p
24 ~ 30V
MDR-60-24
31.2 ~ 36V
88%
1.0%
1.0%
1.0%
M D R - 6 0
File Name:MDR-60-SPEC 2010-12-07
MDR-60-48
48V
1.25A
0 ~ 1.25A
60W
200mVp-p
48 ~ 56V
57.6 ~ 64.8V
87%
1.0%
1.0%
1.0%
s e r i e s

Related parts for MDR-60-5

MDR-60-5 Summary of contents

Page 1

... Single Output Industrial DIN Rail Power Supply SPECIFICATION MODEL MDR-60-5 DC VOLTAGE 5V RATED CURRENT 10A CURRENT RANGE 0 ~ 10A RATED POWER 50W RIPPLE & NOISE (max.) 80mVp-p Note.2 OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME 500ms, 30ms/230VAC Note ...