RS-25-24 Mean Well, RS-25-24 Datasheet

Linear & Switching Power Supplies 26.4W 24V 1.1A

RS-25-24

Manufacturer Part Number
RS-25-24
Description
Linear & Switching Power Supplies 26.4W 24V 1.1A
Manufacturer
Mean Well
Datasheet

Specifications of RS-25-24

Product
Switching
Output Power Rating
26 W
Input Voltage
88 VAC to 264 VAC, 125 VDC to 373 VDC
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
1.1 A
Mounting Style
Screw
Dimensions
79 mm L x 51 mm W x 28 mm H
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 6)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
25W Single Output Switching Power Supply
Note.4
Note.5
Note.3
Note.2
RS-25-3.3
3.3V
6A
0 ~ 6A
19.8W
80mVp-p
2.85 ~ 3.6V
1800ms, 23ms/230VAC
80ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
0.2Kg; 60pcs/13Kg/0.46CUFT
110 ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut off o/p voltage, clamping by zener diode
-20 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
309.7Khrs min.
78*51*28mm (L*W*H)
73.5%
0.7A/115VAC
COLD START 30A/230VAC
<2mA / 240VAC
3.8 ~ 4.45V
3.0%
0.5%
2.0%
0.03%/
(0 ~ 50 )
(Refer to output load derating curve)
I/P-FG:1.5KVAC
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
MIL-HDBK-217F (25 )
0.4A/230VAC
14ms/115VAC at full load
RS-25-5
5V
5A
0 ~ 5A
25W
80mVp-p
4.75 ~ 5.5V
78.5%
5.75 ~ 6.75V
2.0%
0.5%
1.0%
4000ms, 30ms/115VAC at full load
O/P-FG:0.5KVAC
RS-25-12
12V
2.1A
0 ~ 2.1A
25.2W
120mVp-p
10.8 ~ 13.2V
81.5%
13.8 ~ 16.2V
1.0%
0.5%
0.5%
RS-25-15
15V
1.7A
0 ~ 1.7A
25.5W
120mVp-p
13.5 ~ 16.5V
83.5%
17.25 ~ 20.25V
1.0%
0.5%
0.5%
RS-25-24
24V
1.1A
0 ~ 1.1A
26.4W
120mVp-p
22 ~ 27.6V
86%
27.6 ~ 32.4V
1.0%
0.5%
0.5%
R S - 2 5
File Name:RS-25-SPEC 2010-10-18
RS-25-48
48V
0.57A
0 ~ 0.57A
27.36W
200mVp-p
42 ~ 54V
85%
55.2 ~ 64.8V
1.0%
0.5%
0.5%
s e r i e s

Related parts for RS-25-24

RS-25-24 Summary of contents

Page 1

... Without damage) 78.5% 81.5% 0.4A/230VAC 5.75 ~ 6.75V 13.8 ~ 16.2V (Refer to output load derating curve) 0.03 I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( RS-25-15 RS-25-24 RS-25-48 15V 24V 48V 1.7A 1.1A 0.57A 0.57A 25.5W 26.4W 27.36W 120mVp-p ...

Page 2

... Case No.931A 55 10.5 78 66.5 2.75 RECTIFIERS +V & -V FILTER DETECTION CIRCUIT 60 80 100 120 140 160 180 200 220 INPUT VOLTAGE (VAC) 60Hz File Name:RS-25-SPEC 2010-10- Unit:mm fosc : 60KHz Ta=25 300 250 200 150 100 50 25 240 264 ...