N-51X Triad Magnetics, N-51X Datasheet

no-image

N-51X

Manufacturer Part Number
N-51X
Description
Transformers 115/115V 35VA XFMR ISOLATION XFMR
Manufacturer
Triad Magnetics
Type
Transformers and Autotransformersr
Datasheets

Specifications of N-51X

Dimensions
93.17 mm W x 57.93 mm H
Product
Isolation Transformers
Height
57.93 mm
Width
93.17 mm
Brand/series
N Series
Capacity
35 VA
Configuration
Bobbin
Current, Secondary
0.3 A
Frequency
50/60 Hz
Hipot Rating
1500 V (RMS)
Length, Lead
7 "
Mounting Hole Centers
3.125 "
Mounting Type
Panel/Chassis
Number Of Outlets
1
Phase
1
Power, Rating
35 VA
Standards
UL Listed
Termination
Leadwires
Voltage, Primary
115 VAC
Voltage, Rating
115 V
Voltage, Secondary
115 VAC
Weight
1.7 lbs.
Power Rating
35 VA
Primary Voltage Rating
115 V
Mounting Style
Foot
Length
2.125 in
Termination Style
Wire Leads
Primary Voltages
115V
Secondary Voltages
115 VAC
Current Rating
300mA
Transformer Mounting
Chassis
Secondary Current Nom
0.3A
No. Of Phases
Single
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Input Voltage
115VAC
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
N-51X
Electrical Specifications (@25°C)
1. Maximum Power:
2. Input Voltage:
3. Output Voltage:
4. Full Secondary Load: 0.30 Amps RMS
5. Voltage Regulation: 15 % TYP @ full load to no load
Description:
The N-51X is power transformer for isolating equipment from direct connection to the
power line. It is constructed with nonconcentrically wound coils. The primary and
secondary are wound on separate arbors, then assembled on a laminate core
side-by-side separated by insulation. This prevents electrical connection under
normal or overload conditions between the primary and secondary windings.
Safety:
These units are designed with 1500V isolation between winding to winding and
between winding and core. Materials and construction are rated for Class B
insulation system.
Dimensions:
Weight: 1.70 lbs
Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin
Schematic:
Input: Blk to Blk
Output: Red to Red
Shield: Wht
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
2.281
A
3.687
B
As of manufacturing date February 2005, all standard
2.125
C
Unit: In inches
35 VA
115 V, 50 / 60 Hz
115V + 5%
3.125
D
BLK
BLK
WHT
RED
RED
P
C
HASSIS
O W E R
M
T
OUNT :
R A N S F O R M E R
Isolation
A
B
D
C

Related parts for N-51X

N-51X Summary of contents

Page 1

... Full Secondary Load: 0.30 Amps RMS 5. Voltage Regulation TYP @ full load to no load Description: The N-51X is power transformer for isolating equipment from direct connection to the power line constructed with nonconcentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation ...

Page 2

... The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents : : Type Primary Volts Section No. VA Voltage ±5% A N-48X 15 115 115.0 B N-51X 35 115 115.0 C N-68X 50 115/230§ 115.0 N-53M 85 115 115.0 D N-53MG 85 115 115.0 N-76U* ...

Page 3

... Type Primary Volts Section No. VA Voltage ±5% N-57MG 500 115 115.0 A N-257MG 500 230 115.0 N-59M 1,000 115 115.0 B N-59MG 1,000 115 115.0 N-259MG 1,000 230 115.0 With ground wire Mounting hole sizes: ( " Line cord, plug and receptacle are U.L. listed and verified to meet federal specifications. ...

Related keywords