DCA-20PC-5-DC4-BS-C Murata Power Solutions Inc, DCA-20PC-5-DC4-BS-C Datasheet - Page 2

Digital Panel Meters 0-1.999A input range 3 1/2 Digit Blue LED

DCA-20PC-5-DC4-BS-C

Manufacturer Part Number
DCA-20PC-5-DC4-BS-C
Description
Digital Panel Meters 0-1.999A input range 3 1/2 Digit Blue LED
Manufacturer
Murata Power Solutions Inc
Type
AC Ammetersr
Datasheet

Specifications of DCA-20PC-5-DC4-BS-C

Equipment Type
AC Ammeters
Display Type
4 - 1/2 Digit LCD
Dimensions
46.38 mm L x 32.51 mm W x 4.75 mm H
Mounting Style
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
DCA-20PC-5-DC4-BS-C
Performance/Functional Specifi cations
Typical at T
Full Scale Load Current ➀
DCA-20PC-1
DCA-20PC-2
DCA-20PC-3
DCA-20PC-4
DCA-20PC-5
DCA-20PC-6
Overcurrent Rating (<6 sec.) ➁
Internal Shunt Resistance
DCA-20PC-1
DCA-20PC-2
DCA-20PC-3
DCA-20PC-4
DCA-20PC-5
DCA-20PC-6
Shunt Input to Power Supply Isolation ➂
DCA-20PC-X-DC4 models only
Performance
Sampling Rate
Accuracy
Zero-Current Reading ➃
Temperature Drift (0 = +60°C)
Operating Supply Voltage (TB2 Terminals 1, 2 and 3) ➄
DCA-20PC-X-DC1-XX
DCA-20PC-X-DC4-XX
Operating Supply Current (TB2 Terminals 1, 2 and 3) ➄
DCA-20PC-X-DC1-XX (@ 5-40V)
DCA-20PC-X-DC4-XX (@ 8V)
DCA-20PC-X-DC4-XX (@ 36V)
TB1 and TB2 Terminal Blocks
Wire Size
Insulation Strip Length
Screw Tightening Torque
Rated Current
Display
Display Type and Size
Overrange Indication
Display Reading/Decimal Point
Physical/Environmental
Operating Temperature
Storage Temperature
A
= +25°C, unless otherwise noted.
“–001”
3½ digit, 0.37"/9.4mm high red, blue or
Min.
+5.0
500
–20
+8
20A with 12AWG solid copper wire;
14-20AWG, (stranded) copper wire
0
15A with 14AWG solid or stranded
1.5x rated full-scale load current
"–1_ _ _" for negative Vin
4.4 pound/inches (0.5Nm)
2.5 reading per second
"1_ _ _" for positive Vin
12-20AWG, (solid)
Model dependent
Typ.
“000”
±0.2
100
10
25
0.250 inches
green LED
±0.15%FS
copper wire
Max.
199.9
1.999
19.99
199.9
1.999
19.99
0.001
“001”
±0.4
0.01
100
+40
+36
150
+60
+75
1.0
0.1
10
15
40
www.murata-ps.com/dpm
Volts
Cnts/°C
Units
Counts
Ohms
Ohms
mAdc
mAdc
mAdc
mAdc
mAdc
mAdc
μAdc
Ohm
Ohm
Ohm
Ohm
Adc
Adc
Vdc
Vdc
°C
°C
➀ The noted full-scale values are the external load currents that the ammeter is
➁ For all models, the application of 1.5 times the rated full-scale load current is
➂ Breakdown (isolation) voltage applies only to ‘-DC4’ isolated-power models. Break-
➃ Zero reading is measured with TB1-1 (-SHUNT) shorted to TB1-2 (+SHUNT).
➄ The Operating power supply voltage is applied to TB2-1-2 (+V) and TB2-3 (-V)
Ordering Information
Physical/Environmental (continued)
Humidity (non-condensing)
Case Material
Dimensions
Weight
Measuring positive and negative currents (bipolar operation): In applications
On 5-40Vdc powered (‘-DC1’), grounded-shunt models, the ammeter’s operating
designed to measure. This current enters TB-1 (-SHUNT), passes through the am-
meter’s built-in shunt and exits via TB1-2 (+SHUNT). For all models, this same full-
scale load current can also be routed, if the user so chooses, through TB2-1 and
TB2-2 (connection to positive rail of power supply). See detailed wiring diagrams.
where both positive and negative currents must be measured, Murata Power Solu-
tions recommends using ‘-DC4’ 8-36V isolated supply models. Negative current
fl ow is denoted by the illumination of the display’s negative (-) sign; the absence
of a negative sign implies positive current fl ow. Contact MPS if you have any ques-
tions regarding bipolar operation of DCA-20PC ammeters.
permissible as long as this overcurrent condition does not exceed 6 seconds and
occurs no more than once in a 60 second interval (10% duty cycle).
down voltage is tested with TB1-1 tied to TB1-2 (-SHUNT shorted to +SHUNT),
and TB2-1, TB2-2, and TB2-3 all tied together (+V shorted to -V). 500Vdc is then
applied between the two shorted terminal-block pairs; the maximum permissible
leakage current is 5uA.
on ‘-DC4’ models, and to TB1-1 (-SHUNT) and TB2-2 (+V) on ‘-DC1’ models. On
all models, TB2-1 and TB2-2 are internally tied together (+V). Operating supply
current is the current which powers the meter’s analog and digital circuits; it is
measured with zero load-current passing through the ammeter’s built-in shunt
(i.e., with the display reading “000” and one decimal point enabled).
supply current enters TB1-1 (-Shunt) but is not included in the displayed reading
(i.e., it does not pass through the built-in shunt).
Input Range:
Full-scale load current
DCA-20PC - 1 - DC1 - R L - C
1 = 199.9μA
2 = 1.999mA
3 = 19.99mA
4 = 199.9mA
5 = 1.999A
6 = 19.99A
Accessories:
DMS-20-CP Panel Cutout Punch
A DMS-BZL4-C bezel assembly with sealing gasket is
supplied with each ammeter.
LED Display, Subminiature DC Ammeters
Power Supply:
DC1 = +5-40Vdc, non-isolated power
DC4 = +8-36Vdc, isolated power
29 Mar 2011 MPM_DCA-20PC.B06 Page 2 of 6
DCA-20PC Series
(available with -RL, -BL, or -PGL LEDs)
(available with -RL, -BS, or -GS LEDs)
0
1.38"W x 0.88" x 1.0" nominal
0.6 ounces (17 grams)
with Built-In Shunts
email: sales@murata-ps.com
LED Color:
Polycarbonate
BL = Low-Power Blue
BS = Super Blue
GS = Standard Green
PGL = Low-Power Green
RL = Low-Power Red
Add -C for RoHS
85
%