C1812X102KHRACTU Kemet, C1812X102KHRACTU Datasheet - Page 8

no-image

C1812X102KHRACTU

Manufacturer Part Number
C1812X102KHRACTU
Description
CAP CER 1000PF 3000V X7R 1812 FT
Manufacturer
Kemet
Series
HV FT-CAPr
Datasheet

Specifications of C1812X102KHRACTU

Voltage - Rated
3000V (3kV)
Capacitance
1000pF
Tolerance
±10%
Temperature Coefficient
X7R
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 125°C
Features
High Voltage, Soft Termination
Applications
Boardflex Sensitive
Package / Case
1812 (4532 Metric)
Size / Dimension
0.181" L x 0.126" W (4.60mm x 3.20mm)
Thickness
0.071" (1.80mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ratings
-
Lead Spacing
-
Other names
399-5848-2
Table 4 – Performance & Reliability: Test Methods and Conditions
SMD MLCCs – High Voltage with Flexible Termination System (HV FT-CAP), X7R Dielectric, 500VDC-3000VDC (Commercial Grade)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Resistance to Solvents
High Temperature Life
Temperature Cycling
Moisture Resistance
Mechanical Shock
Terminal Strength
Biased Humidity
Thermal Shock
Ripple Current
Solderability
Storage Life
Board Flex
Stress
MIL-STD-202 Method 103
MIL-STD-202 Method 106
MIL-STD-202 Method 107
MIL-STD-202 Method 108
MIL-STD-202 Method 108
MIL-STD-202 Method 213
MIL-STD-202 Method 215
JESD22 Method JA-104
"Heat Generation
∆T : 20ºC max."
Reference
JIS-C-6429
JIS-C-6429
J-STD-002
"Reflow solder the capacitor onto a PC board and apply voltage with 10kHz~1Mhz sine curve.
(Ripple voltage must be < rated voltage)"
Appendix 1, Note: Force of 1.8kg for 60 seconds.
Appendix 2, Note: 2mm (min) for all except 3mm for C0G.
Magnification 50X. Conditions:
1000 Cycles (-55°C to +125°C), Measurement at 24 hrs. +/- 2 hrs after test conclusion.
Load Humidity: 1000 hours 85°C/85%RH and 300VDC Max. Add 100K ohm resistor. Measurement
at 24 hrs. +/- 2 hrs after test conclusion.
Low Volt Humidity: 1000 hours 85C°/85%RH and 1.5V. Add 100K ohm resistor. Measurement at
24 hrs. +/- 2 hrs after test conclusion.
t = 24 hours/cycle. Steps 7a & 7b not required. Unpowered. Measurement at 24 hrs. +/- 2 hrs after
test conclusion.
-55°C/+125°C. Note: Number of cycles required-300, Maximum transfer time-20 seconds, Dwell
time-15 minutes. Air-Air.
1000 hours at 125°C (85°C for X5R, Z5U and Y5V) with rated voltage applied.
150°C, 0VDC, for 1000 Hours.
Figure 1 of Method 213, Condition F.
Add Aqueous wash chemical - OKEM Clean or equivalent.
a) Method B, 4 hrs @ 155°C, dry heat @ 235°C
b) Method B @ 215°C category 3
c) Method D, category 3 @ 260°C
Test or Inspection Method
C1025-1 • 9/13/2010
8

Related parts for C1812X102KHRACTU