901-128-11 AMPHENOL RF, 901-128-11 Datasheet

CONN SMA PLUG STRAIGHT CABLE MNT

901-128-11

Manufacturer Part Number
901-128-11
Description
CONN SMA PLUG STRAIGHT CABLE MNT
Manufacturer
AMPHENOL RF
Series
SMAr
Datasheet

Specifications of 901-128-11

Connector Style
SMA
Connector Type
Plug, Male Pins
Contact Termination
Clamp and Solder
Impedance
50 Ohm
Mounting Type
Free Hanging (In-Line)
Fastening Type
Threaded
Cable Group
RG-174, 188A
Frequency - Max
12.4GHz
Frequency-max
12.4GHz
Body Style
Straight Plug
Coaxial Termination
Solder / Clamp
Rg Cable Type
RG-174, 316
Contact Material
Beryllium Copper
Contact Plating
Gold
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Color
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ARF1188
Assembly Instructions-C44
SMA
MODIFIED CLAMP TYPE FOR FLEXIBLE CABLES
Step 1
Step 2
Step 3
Step 4
Amphenol Corporation Tel: 800-627-7100
901-128-11
Amphenol
Number
Connector
SMA Plug
Type
gasket
clamp nut
assembly
a
b
c
bushing - contact
174, 316
RG-/U
Cable
assembly
315
Step 1 Strip cable to dimensions shown in table. Cut must be
Step 2 Place clamp assembly over braid and push back against
Step 3 (For angle connectors, skip to next step.) Assemble bushing
Step 4 Thread connector assembly onto prepared cable assembly.
square. Do not nick center conductor. Comb out braid.
cable jacket. Fold back braid wires, trim as necessary so
that wires do not touch shoulder of gasket.
assembly and solder center contact to cable (SN60-40 rosin
core solder recommended.)
Tighten to 20-25 in/lbs torque. For angle connectors, solder
center conductor and cap in place.
plug body assembly
.328(14)
a
Stripping Dimensions, inches (mm)
b
Amphenol
www.amphenolrf.com
.125(3.2)
c
®

Related parts for 901-128-11