PC28F256J3F95A NUMONYX, PC28F256J3F95A Datasheet - Page 24

no-image

PC28F256J3F95A

Manufacturer Part Number
PC28F256J3F95A
Description
IC FLASH 256MBIT 95NS 64EZBGA
Manufacturer
NUMONYX
Series
StrataFlash™r
Datasheet

Specifications of PC28F256J3F95A

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
256M (32M x8, 16M x16)
Speed
95ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TBGA
Cell Type
NOR
Density
256Mb
Access Time (max)
95ns
Interface Type
Parallel
Address Bus
25/24Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
EZBGA
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
32M/16M
Supply Current
31mA
Mounting
Surface Mount
Pin Count
64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
898244
898244
PC28F256J3F95 898244

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PC28F256J3F95A
Manufacturer:
HYNIX
Quantity:
1 000
Part Number:
PC28F256J3F95A
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Company:
Part Number:
PC28F256J3F95A
Quantity:
40
Company:
Part Number:
PC28F256J3F95A
Quantity:
40
Company:
Part Number:
PC28F256J3F95A
Quantity:
40
8.0
8.1
Note:
8.2
Datasheet
24
Program operation
All programming operations require the addressed block to be unlocked, and a valid
VPEN voltage applied throughout the programming operation. Otherwise, the
programming operation will abort, setting the appropriate Status Register error bit(s).
The following sections describe each programming method.
Single-Word/Byte Programming
Array programming is performed by first issuing the Single-Word/Byte Program
command. This is followed by writing the desired data at the desired array address. The
read mode of the device is automatically changed to Read Status Register mode, which
remains in effect until another read-mode command is issued.
During programming, STS and the Status Register indicate a busy status (SR.7 = 0).
Upon completion, STS and the Status Register indicate a ready status (SR.7 = 1). The
Status Register should be checked for any errors (SR.4), then cleared.
Issuing the Read Array command to the device while it is actively programming causes
subsequent reads from the device to output invalid data. Valid array data is output only
after the program operation has finished.
Standby power levels are not realized until the programming operation has finished.
Also, asserting RP# aborts the programming operation, and array contents at the
addressed location are indeterminate. The addressed block should be erased, and the
data re-programmed. If a Single-Word/Byte program is attempted when the
corresponding block lock-bit is set, SR.1 and SR.4 will be set.
Buffered Programming
The device features a 512-word buffer to enable optimum programming performance.
For Buffered Programming, data is first written to an on-chip write buffer. Then the
buffer data is programmed into the flash memory array in buffer-size increments. This
can improve system programming performance significantly over non-buffered
programming. (see
When the Buffered Programming Setup command is issued, Status Register information
is updated and reflects the availability of the buffer. SR.7 indicates buffer availability: if
set, the buffer is available; if cleared, the buffer is not available. To retry, issue the
Buffered Programming Setup command again, and re-check SR.7. When SR.7 is set,
the buffer is ready for loading.
On the next write, a word count is written to the device at the buffer address. This tells
the device how many data words will be written to the buffer, up to the maximum size
of the buffer.
On the next write, a device start address is given along with the first data to be written
to the flash memory array. Subsequent writes provide additional device addresses and
data. All data addresses must lie within the start address plus the word count.
Optimum programming performance and lower power usage are obtained by aligning
the starting address at the beginning of a 512-word boundary (A[9:1] = 0x00). The
maximum buffer size would be 256-word if the misaligned address range is crossing a
512-word boundary during programming.
After the last data is written to the buffer, the Buffered Programming Confirm command
must be issued to the original block address. The WSM begins to program buffer
contents to the flash memory array. If a command other than the Buffered
Figure 19, “Buffer Program Flowchart” on page
Numonyx™ StrataFlash
®
Embedded Memory (J3-65nm)
59).
December 2008
319942-02

Related parts for PC28F256J3F95A