Page 1
... Analog Devices. Low Cost Dual Axis GENERAL DESCRIPTION The ADXL202/ADXL210 are low cost, low power, complete 2-axis accelerometers with a measurement range of either The ADXL202/ADXL210 can measure both dy- namic acceleration (e.g., vibration) and static acceleration (e.g., gravity). ...
Page 2
ADXL202/ADXL210–SPECIFICATIONS Parameter SENSOR INPUT 1 Measurement Range Nonlinearity 2 Alignment Error Alignment Error 3 Transverse Sensitivity SENSITIVITY Duty Cycle per g Sensitivity, Analog Output 4 Temperature Drift ZERO g BIAS LEVEL 0 g Duty Cycle Initial Offset 0 g Duty ...
Page 3
... JC 14-Lead CERPAK 110 C/W 30 C/W Model ADXL202JQC ADXL202AQC ADXL210JQC ADXL210AQC CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADXL202/ADXL210 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges ...
Page 4
ADXL202/ADXL210 TYPICAL CHARACTERISTICS 1.06 1.04 1.02 1.00 0.98 0.96 0.94 –45 –30 – TEMPERATURE – C Figure 2. Normalized DCM Period (T2) vs. Temperature 0.8 0.6 0.4 0.2 0 –0.2 –0.4 –0.6 –0.8 –40 –30 –20 –10 ...
Page 5
DUTY CYCLE OUTPUT – % per g Figure 8. Typical Sensitivity per ...
Page 6
ADXL202/ADXL210 DEFINITIONS T1 Length of the “on” portion of the cycle. T2 Length of the total cycle. Duty Cycle Ratio of the “on” time (T1) of the cycle to the total cycle (T2). Defined as T1/T2 for the ADXL202/ ADXL210. ...
Page 7
... T2 period. When selecting a microcontroller it is helpful to have a counter timer port available. The microcontroller should have provisions for software calibration. While the ADXL202/ADXL210 are highly accurate accelerometers, they have a wide tolerance for –7– ADXL202/ADXL210 T2 C ...
Page 8
ADXL202/ADXL210 initial offset. The easiest way to null this offset is with a calibra- tion factor saved on the microcontroller user calibration for zero g. In the case where the offset is calibrated during manu- facture, there ...
Page 9
... MEASURING 360 OF TILT It is possible to measure a full 360 of orientation through grav- ity by using two accelerometers oriented perpendicular to one another (see Figure 15). When one sensor is reading a maxi- mum change in output per degree, the other is at its minimum. 0 ...
Page 10
ADXL202/ADXL210 USING THE ANALOG OUTPUT The ADXL202/ADXL210 was specifically designed for use with its digital outputs, but has provisions to provide analog outputs as well. Duty Cycle Filtering An analog output can be reconstructed by filtering the duty cycle output. ...
Page 11
SEATING REV. B OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 14-Lead CERPAK (QC-14) 0.390 (9.906) MAX 14 8 0.419 (10.643) 0.394 (10.008 PIN 1 0.300 (7.62) 0.195 (4.953) 0.115 ...