AD597AHZ Analog Devices Inc, AD597AHZ Datasheet

IC,TEMPERATURE SENSOR,BIPOLAR,CAN,10PIN,METAL

AD597AHZ

Manufacturer Part Number
AD597AHZ
Description
IC,TEMPERATURE SENSOR,BIPOLAR,CAN,10PIN,METAL
Manufacturer
Analog Devices Inc
Datasheets

Specifications of AD597AHZ

Rohs Compliant
YES
Function
Thermocouple Conditioner
Topology
Ice Point Compensation
Sensor Type
External
Sensing Temperature
-200°C ~ 1250°C
Output Type
Voltage
Output Alarm
Yes
Output Fan
No
Voltage - Supply
5 V ~ 30 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Through Hole
Package / Case
TO-100, Metal Can (10 Leads)
Bandwidth
15kHz
Supply Voltage Min
5V
Supply Voltage Max
30V
Digital Ic Case Style
SOIC
No. Of Pins
10
Operating Temperature Range
-55°C To +125°C
Svhc
No SVHC (15-Dec-2010)
Accuracy
4°C
Base Number
597
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
a
GENERAL DESCRIPTION
The AD596/AD597 is a monolithic temperature setpoint con-
troller that has been optimized for use at elevated temperatures
such as those found in oven control applications. The device
cold junction compensates and amplifies a type J or K thermo-
couple input to derive an internal signal proportional to tem-
perature. The internal signal is then compared with an externally
applied setpoint voltage to yield a low impedance switched output
voltage. Dead-Band or switching hysteresis can be programmed
using a single external resistor. Alternately, the AD596/AD597 can
be configured to provide a voltage output (10 mV/ C) directly from
a type J or K thermocouple signal. It can also be used as a stand-
alone voltage output temperature sensor.
The AD596/AD597 can be powered with a single supply from
+5 V to +30 V, or dual supplies up to a total span of 36 V.
Typical quiescent supply current is 160 A, which minimizes
self-heating errors.
The AD596/AD597 H package option includes a thermocouple
failure alarm that indicates an open thermocouple lead when
operated in the temperature proportional measurement mode.
The alarm output has a flexible format which can be used to
drive relays, LEDs or TTL logic.
The device is packaged in a reliability qualified, cost effective
10-pin metal can or SOIC and is trimmed to operate over an
ambient temperature range from +25 C to +100 C. Operation
over an extended ambient temperature range is possible with
slightly reduced accuracy. The AD596 will amplify thermo-
couple signals covering the entire –200 C to +760 C tempera-
ture range recommended for type J thermocouples while the
AD597 can accommodate –200 C to +1250 C type K inputs.
The AD596/AD597 has a calibration accuracy of 4 C at an
ambient temperature of 60 C and an ambient temperature
stability specification of 0.05 C/ C from +25 C to +100 C. If
higher accuracy, or a lower ambient operating temperature is
required, either the AD594 (J thermocouple) or AD595 (K
thermocouple) should be considered.
*Protected by U.S. Patent No. 4,029,974.
REV. B
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
FEATURES
Low Cost
Operates with Type J (AD596) or Type K (AD597)
Built-In Ice Point Compensation
Temperature Proportional Operation – 10 mV/ C
Temperature Setpoint Operation – ON/OFF
Programmable Switching Hysteresis
High Impedance Differential Input
Thermocouples
PRODUCT HIGHLIGHTS
1. The AD596/AD597 provides cold junction compensation
2. The input stage of the AD596/AD597 is a high quality in-
3. Linearization not required for thermocouple temperatures
4. Cold junction compensation is optimized for ambient tem-
5. In the stand-alone mode, the AD596/AD597 produces an
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
Fax: 781/326-8703
Thermocouple Conditioner and
and a high gain amplifier which can be used as a setpoint
comparator.
strumentation amplifier that allows the thermocouple to float
over most of the supply voltage range.
close to 175 C (+100 C to +540 C for AD596).
peratures ranging from +25 C to +100 C.
output voltage that indicates its own temperature.
HYS
FUNCTIONAL BLOCK DIAGRAM
+IN
GND
HYS
+IN
V–
POINT
COMP
1
2
3
4
ICE
GND
–IN
World Wide Web Site: http://www.analog.com
AD597
Setpoint Controller
(Not to Scale)
AD596*/AD597*
ICE POINT
TOP VIEW
+
TO-100
G
–ALM
SOIC
COMP
+
+
+
G
V–
G
+
G
AD596/
AD597
+
+
A
© Analog Devices, Inc., 1998
+
A
+ALM
FB
8
7
6
5
–IN
V+
V
FB
OUT
V+
V
OUT

Related parts for AD597AHZ

AD597AHZ Summary of contents

Page 1

FEATURES Low Cost Operates with Type J (AD596) or Type K (AD597) Thermocouples Built-In Ice Point Compensation Temperature Proportional Operation – 10 mV/ C Temperature Setpoint Operation – ON/OFF Programmable Switching Hysteresis High Impedance Differential Input GENERAL DESCRIPTION The ...

Page 2

AD596/AD597–SPECIFICATIONS Model Min ABSOLUTE MAXIMUM RATINGS +V to – Common-Mode Input Voltage (–V Differential Input Voltage –V S Alarm Voltages +ALM –V S –ALM –V S Operating Temperature Range –55 Output Short Circuit to Common Indefinite TEMPERATURE MEASUREMENT ...

Page 3

Table I. Output Voltage vs. Thermocouple Temperature (Ambient + Thermocouple Type J AD596 Temperature Voltage Output –200 –7.890 –1370 –180 –7.402 –1282 –160 –6.821 –1177 –140 –6.159 –1058 –120 –5.426 –925 –100 –4.632 –782 –80 ...

Page 4

AD596/AD597 TEMPERATURE PROPORTIONAL OUTPUT MODE The AD596/AD597 can be used to generate a temperature proportional output of 10 mV/ C when operated with J and K type thermocouples as shown in Figure 1. Thermocouples pro- duce low level output voltages ...

Page 5

SETPOINT CONTROL MODE The AD596/AD597 can be connected as a setpoint controller as shown in Figure 2. The thermocouple voltage is cold junction compensated, amplified, and compared to an external setpoint voltage. The relationship between setpoint voltage and tempera- ture ...

Page 6

AD596/AD597 SINGLE AND DUAL SUPPLY CONNECTIONS In the single supply configuration as used in the setpoint con- troller of Figure 2, any convenient voltage from + +36 V may be used, with self-heating errors being minimized at lower ...

Page 7

TEMPERATURE CONSTANTAN (ALUMEL) IRON (CHROMEL) HEATER REV 470 – AD596/ 45.2k AD597* 10k 1.27M +V 5V 40.2k AD584 10k – 1k SET-POINT ADJUST 10k OP07 5k + 10M Figure 6. Temperature Measurement and Control –7– AD596/AD597 ...

Page 8

AD596/AD597 0.040 (1.02) MAX OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 10-Pin Metal Can (TO-100) REFERENCE PLANE 0.750 (19.05) 0.500 (12.70) 0.185 (4.70) 0.160 (4.06) 0.165 (4.19) 0.250 (6.35) MIN 0.110 (2.79) 0.050 (1.27) MAX 6 5 0.115 4 ...

Related keywords