8502SCO2V02S SQUARE D, 8502SCO2V02S Datasheet - Page 46

CONTACTOR, 3PST, 120VAC, 27A, PANEL

8502SCO2V02S

Manufacturer Part Number
8502SCO2V02S
Description
CONTACTOR, 3PST, 120VAC, 27A, PANEL
Manufacturer
SQUARE D
Datasheets

Specifications of 8502SCO2V02S

No. Of Poles
3
Contact Configuration
3PST
Relay Mounting
Panel
Coil Voltage Vac Nom
120V
Relay Terminals
Wire Leaded
Contact Voltage Ac Nom
600V
Contact Current Max
27A
Current, Rating
27 A
Enclosure Type
Open
Horse Power Rating
7.5 @ 230 VAC, 10 @ 480 VAC
Relay Type
Contactor
Standards
UL Listed File E78351 CCN NLDX - CSA Certified File LR60905 Class 3211 04
Termination
Screw Clamp
Voltage, Coil
120 VAC
Voltage, Rating
600 VAC
Operating Voltage
600VAC
Switching Power Ac3
10hp
Switching Current Ac3
27A
Load Current Inductive
27A
Load Current Resistive
27A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Line Voltage — with Melting Alloy Overload Relays or Solid State Overload Relays – Class 8810
5/98
Special Arrangements with Three Devices
Three Type S Contactors can be mechanically
interlocked so that only one contactor can be
energized at any one time. The mechanical
interlock, pictured in Figure 2, is an interference
(non-jamming) type locking at the beginning of the
stroke of any contactor.
Factory assembled units are listed in the table
below. Figures 1 and 2 show factory assembled
and wired devices. All contactors are both
electrically and mechanically interlocked. The
class and type numbers listed only cover the
contactor and/or starter mounting arrangement,
NEMA size of the devices, and the number of
poles. A power and control wiring diagram must
accompany each order. Additional electrical
interlocks are available factory (or field) installed
in the locations shown in Figure No. 2 and Table
No. 2, Page 52. 8810 starters are supplied with
melting alloy type thermal overload relays.
For customer assembled units, the basic
mechanical interlock and base assembly can be
purchased separately. Standard Class 8502
contactors and Class 8536 starters are used in
the locations and pole arrangement shown. If
Class 8536 starters are used, it is necessary to
mount a Class 9999 Type SO bracket below the
overload block to give the block support.
For electrically interlocking customer assembled
units a Class 9999 Type SX-12, normally closed
internal interlock and/or a Class 9999 Type SX-7,
normally closed external interlock can be used.
Three Mechanically Interlocked Contactors and Starters — Factory Assembled
Ordering Information Required
1. Order complete factory assembled devices by
2. Supply wiring diagram for power and control
3. Voltage and frequency of contactor coils.
4. Select additional factory assembled electrical
5. Example of ordering information required on
Class Type
8810
8810
class and type number from table above.
connections as catalog number only covers
general contactor and starter mounting
arrangement.
interlocks from table on Page 47 specifying
interlock position letter and whether interlock
is N.O. or N.C.
factory assembled devices:
(a) Class 8810 Type SCO-45
SCO-41 3
SCO-42 4
SCO-43 . . .
SCO-44 . . .
SDO-41 . . .
SDO-42 . . .
SCO-45 3
SCO-46 4
SCO-47 . . .
SCO-48 . . .
SDO-43 . . .
SDO-44 . . .
Contactor Position — See Figure 2
No. 1 Contactor
Size and Poles
NEMA Size 1
No. of Poles
© 1998 Square D All Rights Reserved
NEMA Size 2
No. of Poles
. . .
. . .
3
4
3
4
. . .
. . .
3
4
3
4
No. 2 Contactor
Size and Poles
NEMA Size 1
No. of Poles
3
3
3
3
. . .
. . .
3
3
3
3
. . .
. . .
NEMA Size 2
No. of Poles
. . .
. . .
. . .
. . .
3
3
. . .
. . .
. . .
. . .
3
3
6. For customer assembly of three mechanically
Thermal Units
Thermal units should be ordered separately. For
selection of thermal units, refer to the Catalog
Thermal Unit Selection Index R Digest. Use the
motor nameplate FLC’s (Full Load Currents) to
select thermal units.
Figure 2
Contactor, overload and external electrical
interlock positions
A
B
(b) Wired per diagram
(c) All coils — 120 volts, 60 hertz
(d) Additional electrical interlocks:
interlocked devices, order the mechanical
interlock and overload relay mounting
brackets by class and type numbers.
Cont.
OL-1
No. 3 Contactor
Size and Poles
NEMA Size 1
No. of Poles
3
3
3
3
. . .
. . .
5
5
5
5
. . .
. . .
No.
1
(which must accompany order)
C — N.O., E — N.C., and J — N.O.
C
D
E
F
NEMA Size 2
No. of Poles
. . .
. . .
. . .
. . .
3
3
. . .
. . .
. . .
. . .
5
5
Cont.
OL-2
No.
2
G
H
Overload
Relay
Position
See Fig. 3
OL-2 & -3
OL-2 & -3
K
J
Cont.
OL-3
No.
3
Number of
Thermal
Units
Required
6
6
M
L
OL-35
45

Related parts for 8502SCO2V02S