8910DPA93V09 SQUARE D, 8910DPA93V09 Datasheet - Page 18

CONTACTOR, 3PST-NO, 240VAC, 90A, PANEL

8910DPA93V09

Manufacturer Part Number
8910DPA93V09
Description
CONTACTOR, 3PST-NO, 240VAC, 90A, PANEL
Manufacturer
SQUARE D
Datasheet

Specifications of 8910DPA93V09

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
Panel
Coil Voltage Vac Nom
240V
Relay Terminals
Screw
Contact Voltage Ac Nom
600V
Contact Current Max
90A
Mounting Type
Panel
Operating Voltage
600VAC
Switching Power Ac1
20hp
Switching Power Ac3
50hp
Switching Current Ac1
120A
Switching Current Ac3
90A
Load Current Inductive
90A
Load Current Resistive
120A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Class 9999 — Auxiliary Contacts
18
Auxiliary Contact
Single Circuit
External
External Contacts
Class 9999 Type SX6 through Type SX10 external auxiliary contacts can be added to Type DPA123 and
SYD devices. These contacts mount on either side of the basic contactor and are available with
convertible or non-convertible contacts. The contacts of the convertible version can be changed from
N.O. to N.C. or vice versa in the field.
See table below for electrical ratings.
Class 8910 and 8911 Definite Purpose Contactors and Starters – Auxiliary Contacts
Class 8965 Reversing/Hoist Contactors – Auxiliary Contacts
Maximum Ratings For Auxiliary Contacts
t Type DPA122 and DPA123 use same auxiliary contacts shown below. (Example: Class 9999 Type SX6).
For Use With
Class 8910
Class 9999 Type
DPA 123
Type
SYD
SX6-SX10
Class 8910 or 8911 Type
Device to be Serviced
Device to be Serviced
Class 8965 Type
DPR
RO2 & RG2
RO10 Form X1
RO11 Form X1
RO3 & RG3
RO10 Form X2
RO11 Form X2
RO5 & RG5
RO12 Form X1
RO13 Form X1
RO6 & RG6
RO12 Form X2
RO13 Form X2
External Field Convertible
1-N.O. Contact ..........................................................................................................................
1-N.C. Contact ..........................................................................................................................
1-N.O. and 1-N.C. Isolated Contacts.........................................................................................
1-N.O. Overlapping Contact......................................................................................................
1-N.C. Overlapping Contact......................................................................................................
DPAt
DPS
© 1998 Square D All Rights Reserved
120 or Less
Volts AC
Contact Arrangement
Kit Description
1 N.O.
1 N.C.
1 N.O./1 N.C.
2 N.O.
1 N.O. each side
1 N.C. each side
1 N.O. each side
1 N.C. each side
Contact Arrangement
60 Amps
Make
AC Only (35% Power Factor)
1 N.O.
1 N.C.
1 N.O./1 N.C.
2 N.O.
Contact Ratings
Auxiliary Contact Kit
Auxiliary Contact Kit
Type of Connector
Screw/
Slip-on
Screw
Q. C.
Break
6 Amps
Class 9999 Type
D10
D01
D11
D20
Class 9999 Type
Class 9999
Continuous
Type
SX6
SX7
SX8
SX9u
SX10u
10 Amps
D10
D01
D11
D20
R10
R11
R12
R13
5/98