MKS2PN DC110 Omron, MKS2PN DC110 Datasheet

POWER RELAY, DPDT, 110VDC, 10A, PLUG IN

MKS2PN DC110

Manufacturer Part Number
MKS2PN DC110
Description
POWER RELAY, DPDT, 110VDC, 10A, PLUG IN
Manufacturer
Omron
Datasheet

Specifications of MKS2PN DC110

Relay Type
General Purpose
Coil Voltage Vdc Nom
110V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
8960ohm
Contact Configuration
DPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Exceptionally Reliable General Purpose
Relay now available with Lockable Test
Button
• IEC Rating of 7A 250 V AC 50/60 Hz,
• Mechanical indicator standard for all models.
• Optional features include lockable test button, LED
• UL (RU/
• RoHS Compliant.
Features
Two-way Action Test Button
Model Number Structure
■ Model Number Legend
1. Contact Form
2. Terminals
3. Mechanical Indicator/Test Button
4. LED Indicator
MKS@@@@@-@-@
General use 100,000 cycles.
indicator, diode surge suppression, varistor, reverse
polarity, and alternate wiring styles.
General Purpose Relays
MKS
2:
3:
P:
Blank:Mechanical indicator
I:
Blank: Standard
N:
1 2 3 4 5
DPDT
3PDT
Plug-in
Mechanical indicator and lockable test button
LED indicator
C
RU), CE and TUV approved.
6
7
Normal Operation
Relay in
Yellow
button
Pull down the test
button to the first
position, then press the
yellow button with an
insulated tool to
operate the contact.
For Momentary
Operation
5. Coil Polarity
6. Surge Absorption
7. Internal Connections DPDT
8. Rated Voltage
Blank: Standard
1:
Blank:Standard
D:
V:
Blank: Standard
2 :
Internal Connections 3PDT
5 :
Blank: Non Standard
2 :
(Refer to “Coil Ratings”.)
Reverse polarity (DC coil only)
Surge absorber diode (DC coil only)
Surge absorber varistor (AC coil only)
Non Standard
Standard
Non Standard
Pull down the test
button to the second
position.
(The contact is now in
the locked position.)
General Purpose Relays
Operation
For Lock
MKS
277

Related parts for MKS2PN DC110

MKS2PN DC110 Summary of contents

Page 1

... Reverse polarity (DC coil only) 6. Surge Absorption Blank:Standard D: Surge absorber diode (DC coil only) V: Surge absorber varistor (AC coil only) 7. Internal Connections DPDT Blank: Standard 2 : Non Standard Internal Connections 3PDT 5 : Standard Blank: Non Standard 2 : Non Standard 8. Rated Voltage (Refer to “Coil Ratings”.) General Purpose Relays MKS 277 ...

Page 2

... Sockets (Order Separately) Item Type Track-mounted 8-pin Socket 11-pin 8-pin 11-pin Hold-down Clip (For PF083A-E and PF113A-E) 278 General Purpose Relays Internal connections With mechanical indicator With mechanical indicator (See note 3.) MKS2P MKS2P-2 MKS3P-5 MKS3P-2 MKS3P MKS2PN(1) MKS2PN(1)-2 MKS3PN(1)-5 ...

Page 3

... AgSnIn 10 A, 250 VAC 7 A, 250 VAC 10A, 30 VDC 5 A, 250 VAC VDC 10 A 250 VAC, 250 VDC 10 A 2,500 VA/300 W 1,250 VA/150 W General Purpose Relays Max. voltage Power consumption 110% of rated volt- Approx. 2.3 VA age Approx. 2 Approx. 1.4 W MKS 279 ...

Page 4

... A, 250 V AC 50/60 Hz (Resistive) contact (Resistive 250 V AC 50/60 Hz (General Use) Note: 10A UL ratings are with no load on the other contact set. CSA Certified by Engineering Data ■ Reference Data Maximum Switching Power 100 resistive load with NO contact AC resistive load with NO contact ...

Page 5

... PF083A PF113A-D PF113A PF113A-E (Conforming to EN 50022) Eleven, M3.5 × 7 sems 52 max. Mounting Holes 4 34 42.8 max. Two two 4.5-dia. holes 33±0.2 General Purpose Relays 0.8 52.5 max. Terminal Arrangement 7 4 35.4 Mounting Holes 3.5 2 Two two 4.5-dia. holes 31 max. 33±0.2 ...

Page 6

... The figure in parenthesis is for PFP-50N. Mounting Height with Sockets Two 87.8 77.8 poles (See (See note.) note.) 74.3 PF083A(-E) PF113A(-E) Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting. 282 General Purpose Relays PF113A-D Terminal Arrangement Eight, M4 screws ...

Page 7

... Standard Polarity Diode Type MKS2P(I)1-D (DC Coil Reverse Polarity MKS2P(I)-2 MKS3P( MKS2P(I)N-2 MKS3P(I MKS2P(I)N-2 MKS3P(I MKS2P(I)N1-2 MKS3P(I) MKS2P(I)-D-2 MKS3P(I)- MKS2P(I)1-D-2 MKS3P(I)1 General Purpose Relays (Bottom View) MKS3P(I)-2 MKS3P(I)- MKS3P(I)N-2 MKS3P(I)N MKS3P(I)N-2 MKS3P(I)N MKS3P(I)N1-2 MKS3P(I)N1 MKS3P(I)-D-2 MKS3P(I)-D MKS3P(I)1-D-2 MKS3P(I)1-D MKS ...

Page 8

... Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled. 284 General Purpose Relays MKS2P(I)N-D-2 MKS3P(I)N-D 5 ...

Page 9

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 10

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords