G6RL-1A 12DC Omron, G6RL-1A 12DC Datasheet - Page 2

RELAY, PCB, SPST, 12VDC

G6RL-1A 12DC

Manufacturer Part Number
G6RL-1A 12DC
Description
RELAY, PCB, SPST, 12VDC
Manufacturer
Omron
Datasheet

Specifications of G6RL-1A 12DC

Relay Type
Power
Coil Voltage Vdc Nom
12V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Coil Resistance
654.5ohm
Coil Type
DC Coil
Coil Current
18.3mA
Nom Operating
RoHS Compliant
Contact Configuration
SPST
Rohs Compliant
Yes
G6RL
Note:
2
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value) 10 mA at 5 VDC (P Level)
Contact resistance
Operate time
Release time
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance (Mechanical)
Ambient temperature
Ambient humidity
Weight
Insulation material group
Rated insulation voltage
Pollution degree
Rated voltage system
Over-voltage category
Contact material
Creepage distance
Clearance distance
RoHS
Tracking index of relay base PTI 250
Flammability class accord-
ing to UL94
Flammability-flame
Ball pressure test (IEC
60695-10-2)
Contact Ratings
Characteristics
Other data
GWFI (IEC 60695-2-12)
GWIT (IEC 60695-2-13)
P level: λ 60 = 0.1 × 10
−6
IIIa
250 V
3
250 V
III
AgNi
10 mm
10 mm
Compliant
V-0
850°C
750°C
170°C
Resistive load (cos φ = 1)
8 A at 250 VAC, resistive load
5 A at 24 VDC, resistive load
10 A at 250 VAC
5 A at 30 VDC
400 VAC, 300 VDC
NO: 10 A, NC: 8 A
NO: 2,500 VA, NC: 2,000 VA
150 W
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
10 kV between coil and contacts (1.2 × 50 µs)
Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 to 10 Hz, 0.825-mm single amplitude (1.65-mm double amplitude) when energized.
Destruction: 1,000 m/s
Malfunction: 200 m/s
10,000,000 operations min. (at 18,000 operations/h)
Operating: −40°C to 85°C (with no icing)
Operating: 5% to 85%
Approx. 7.8 g
/ operations
10 to 55 to 10 Hz, 0.4-mm single amplitude (0.8-mm double amplitude) when not energized.
2
NO, 50 m/s
2
2
NC when not energized
2
400 V
G6RL

Related parts for G6RL-1A 12DC