G6E-134P-US 5DC Omron, G6E-134P-US 5DC Datasheet - Page 5

RELAY, PCB, SPCO, 5VDC

G6E-134P-US 5DC

Manufacturer Part Number
G6E-134P-US 5DC
Description
RELAY, PCB, SPCO, 5VDC
Manufacturer
Omron
Datasheet

Specifications of G6E-134P-US 5DC

Contact Current Max
3A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Resistance
125ohm
Coil Power Cont
200mW
Relay
RoHS Compliant
Coil Type
DC Coil, Monostable
Coil Current
40mA
Contact Configuration
SPDT
Rohs Compliant
Yes
Precautions
G6EU-134C-US
G6EU-194C-US
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON
continuously for long periods (without switching) can lead to
unstable contacts because the heat generated by the coil itself
will affect the insulation, causing a film to develop on the contact
surfaces. We recommend using a latching relay (magnetic-holding
relay) in this kind of circuit. If a single-side stable model must be
used in this kind of circuit, we recommend using a fail-safe circuit
design that provides protection against contact failure or coil
burnout.
Installation
Do not reverse the polarity of the coil (+, -).
Provide sufficient space between Relays when mounting two or
more on the same PCB, as shown in the following diagram.
G6EK-134P-US
G6EK-194P-US
G6EK-134C-US
G6EK-194C-US
Text
PCB Signal Relay – G6E
Precautions for Correct Use
Close
mounting
3.16
3.16
Distance between terminals:
2.54 × 2 (pitch) max.
1.6
1.6
0.6
1.6
2.86
0.6
0.6
2.86
5.08
5.08
5.08
5.08
16 max.
(15.9) *
16 max.
(15.9) *
16 max.
(15.9) *
7.62
7.62
7.62
7.62
*Average value
*Average value
*Average value
*Average value
0.25
0.25
0.25
7.62
10 max.
(9.9) *
10 max.
(9.9) *
10 max.
(9.9) *
7.62
7.62
7.62
0.3
Wiring
Refer to the following diagram when wiring to switch a DC load.
The difference in polarity applied to the contacts will affect the
endurance of the Relay due to the amount of contact movement.
To extend the endurance characteristics beyond the performance
ratings, wire the common (pin 7) terminal to the positive (+) side.
Ultrasonic Cleaning
Do not use ultrasonic cleaning on standard relay models. Doing
so may result in resonance, coil burnout, and contact adhesion
within the Relay. Use a model designed for ultrasonic cleaning if
ultrasonic cleaning is required.
Relay Handling
When washing the product after soldering the Relay to a PCB, use
a water-based solvent or alcohol-based solvent, and keep the
solvent temperature to less than 40°C. Do not put the Relay in a
cold cleaning bath immediately after soldering.
0.3
0.3
3.5
8 max.
(7.9) *
8 max.
(7.9) *
8 max.
(7.9) *
Five, 1.0-dia. holes
(1.65)
+
Six, 1.0-dia. holes
Wiring Diagram
(1.65)
Mounting Holes
(Bottom View)
Tolerance: ±0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
Load
5.08
12
Mounting Holes
(Bottom View)
Tolerance: ±0.1
7
+ 1
12
10
Load
5.08
7.62
S 3
10
-
7.62
R
7.62
+ 6
(1.19)
7
7.62
(1.19)
189

Related parts for G6E-134P-US 5DC