IMC06TS Tyco Electronics, IMC06TS Datasheet - Page 3

RELAY, SPDT, C/O, 12V

IMC06TS

Manufacturer Part Number
IMC06TS
Description
RELAY, SPDT, C/O, 12V
Manufacturer
Tyco Electronics
Datasheet

Specifications of IMC06TS

Contact Current Max
2A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
220V
Coil Voltage Vdc Nom
12V
Coil Resistance
1.029kohm
Coil Power Cont
140mW
Relay Mounting
PC Board
External
RoHS Compliant
Coil Type
DC Coil
IM Relay
1 and 2 pole telecom/signal relay, polarized
Through Hole Types (THT), standard version with
5.08 mm, narrow with 3.2 mm between the terminal rows
or Surface Mount Type (SMT)
Relay Types:
Configurations:
ROHS compliant (Directive 2002/95/EC) as per product
date code 0438 / Halogen free
Features
-
-
-
-
-
-
-
-
-
-
-
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Minimum board-space 60 mm
Slim line 10 x 6 mm, 0.39 x 0.24 inch and
Low profile 5.65 mm, 0.222 inch
Switching power 60 W / 62.5 VA
Switching voltage 220 VDC / 250VAC
Switching current 2 / 5 A
Bifurcated contacts
Low coil power consumption
Latching version
Non latching version
High dielectric and surge capability (1.2/50 µs and
10/700 µs) meets Telcordia GR1089, FCC Part 68
and ITU-T K20, K21 and K45 requirements
Meets 1500 Vrms (high dielectric version) between
open contacts as well as Australian clearance
requirements
High mechanical shock resistance up to 300G
functional and 500G survival
o
o
o
o
o
o
2 pole changeover / DPDT / 2 Form C
2 pole break / DPST NC / 2 Form B
2 pole make / DPST NO / 2 Form A
1 pole changeover / SPDT / 1 Form C
1 pole break / SPST NC / 1 Form B
1 pole make / SPST NO / 1 Form A
100 mW
140 mW standard
100 mW high sensitive version
up to 2500 Vrms between open contacts
up to 3000 Vrms between coil and contacts
50 mW ultra high sensitive version
non – latching with 1 coil
latching with 1 coil
AXICOM Telecom, Signal and RF Relays
IM Relay
2
IM
IMD
IME
IMC
IMA
IMB
Typical Applications
-
-
-
-
-
-
-
Versions
-
-
-
Insulation Category
Supplementary insulation according IEC / EN 60950
Working voltage ≤ 300 Vrms
Mains supply voltage ≤ 250 Vrms
Repetitive peak voltage 2500 V
Pollution degree Internal: 1
External: 2
Flammability classification V-0
Maximum operating temperature 85 °C
Meets Australien Requirements between open contacts
Telecommunication
Office and business equipment
Consumer electronics
Measurement and Test equipment
Industrial control
Medical equipment
Automotive applications
High Dielectric Version “C” Type
High Current Version “D” Type
High Contact Resistance Stability Version “P” Type
o
o
o
Access and transmission equipment
Optical Network Terminals
Modems
108-98001 Rev. K
3 of 28

Related parts for IMC06TS