SOLID STATE TIMER SPST-NO, 30SEC, 120VAC

4310A-8-B-1

Manufacturer Part Number
4310A-8-B-1
Description
SOLID STATE TIMER SPST-NO, 30SEC, 120VAC
Manufacturer
ARTISAN CONTROLS
Datasheets

Specifications of 4310A-8-B-1

Contact Configuration
SPST-NO
Nom Input Voltage
120VAC
Delay Time Range
0.1s To 30s
Timing Adjustment
Resistor
Relay Mounting
Plug In
Supply Voltage
115VAC
Time Range Max
30s
Contact Form
SPST-NO
Current, Rating
70 mA-5 A
Function
Timing
Relay Type
Solid State
Repeatability
±1% (Nom.)
Standards
cULus, UL
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-20 °C
Termination
Quick Connect
Timer Type
Single Shot
Timing Range
0.1 to 30 sec.
Voltage, Control
120 VAC
Leaded Process Compatible
Yes
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the
sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of
Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property
Timing Diagram - Wired as Single-Shot Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical & Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timing Diagram - Wired as Interval Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tel: 973-598-9400 • Fax: 973-598-9410 • Toll Free: 800-457-4950
Output Switch
Output Switch
Start Switch
Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA
Terminals 4 & 5
not provided on
fixed models
Start Switch
OPEN
V
OPEN
OFF
OFF
I S I T O U R W E B S I T E A T
Solid State Timers and Controllers
MTG. HOLE
0.25 DIA.
CLOSED
CLOSED
ON
ON
2.0 SQ.
The model 4310 can perform as either an interval timer or as a single-shot
timer. This model controls DC loads to 1 Ampere and AC loads to 10 Amperes.
The AC models provide zero-voltage switching (standard) or random-voltage
switching (cost effective) dependant on the output dash number selected. To
use as a single-shot timer, install a jumper across terminals 6 & 7, then a full
time delay is achieved with only a momentary start switch closure. Without the
jumper, the unit operates as an interval timer, requiring the start switch to be
closed for the entire timing period.
7
6
Full Interval Timing Period
Permitted - Start Switch
Closed Longer then Timing
Period
Full Interval Timing Period
Permitted - Start Switch
Closed Longer then Timing
Period
4310
LOAD
Timing Period vs Timing Resistance Range
Connect 6 to 7
for Single Shot
Operation
:
Switch
Start
AC / DC
www.artisancontrols.com
Voltage
Input
1.25 Max
Full Interval Timing Period NOT
Permitted - Start Switch Closed
Less then Timing Period
Interval / Single-Shot
0.38
0.75
Full Interval Timing Period
Permitted - Start Switch
Closed Less then Timing
Period
Timing Module
Terminals
¼" Male

Related parts for 4310A-8-B-1

4310A-8-B-1 Summary of contents

Page 1

... Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property Tel: 973-598-9400 • Fax: 973-598-9410 • Toll Free: 800-457-4950 Artisan Controls Corporation, 111 Canfield Ave ...

Page 2

... Solid State Timers and Controllers Timing vs Resistance Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Resistor (Ohms Meg 3 Meg 5 Meg 10 Meg Ordering Charts: Fixed (4310F) & Adjustable (4310A Part Number - Operating Voltage - Output Rating - Fixed Time in Seconds - Fixed Time Tolerance -2 (12VDC) -3 (24VDC) -4 (48VDC) 4310F -6 (24VAC) -7 (48VAC) -8 (120VAC) -9 (230VAC) ...

Page 3

... Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property Tel: 973-598-9400 • Fax: 973-598-9410 • Toll Free: 800-457-4950 Artisan Controls Corporation, 111 Canfield Ave ...

Related keywords