Nom Input Voltage
240VAC
Delay Time Range
1s To 1024s
Timing Adjustment
DIP Switch
Relay Mounting
PCB
Time Range Min
1024s
Supply Voltage Min
24VAC
Time Range
1 Sec. To 1024 Sec.
Leaded Process Compatible
Yes
Supply Voltage Max
240VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the
sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of
Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property
Mechanical & Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timing Diagram . . . . . . . . . . . . . . . . . . Setting the DIP Switches . . . . . . . . . . . . . . . . . .
Operating
Voltage
LOAD
Artisan Controls Corporation, 111 Canfield Ave, Bldg B15-18, Randolph, New Jersey 07869, USA
Tel: 973-598-9400 • Fax: 973-598-9410 • Toll Free: 800-457-4950
ON
ON
V
Time
Delay
I S I T O U R W E B S I T E A T
Solid State Timers and Controllers
438USA-INT
Recycle
Time
The model 438USA-INT Universal Switch Adjustable Interval Time Capsule
is an all solid state timer providing interval timing control of any load device
operating from 24 to 240 volts AC. The 438USA-INT controls any one ampere
load such as a relay, Solenoid, or lamp. Timing is set using ten DIP switches.
Interval timing is adjustable from 1 to 1024 seconds in increments of 1 second.
When voltage is applied, the 438USA-INT turns on permitting full load current
to flow. At the end of the preset timing period the 438USA-INT turns off and
permits only leakage current to flow through the load. To repeat a cycle, the
operating voltage must be removed for at least 100 milliseconds.
Time
Delay
Switch #1 will add 1 second to
the timing period when open.
Switch #2 will add 2 seconds to
the timing period when open.
Switch #3 will add 4 seconds to
the timing period when open.
Switch #4 will add 8 seconds to
the timing period when open.
This binary progression
permits delay periods ranging
from 1 second to 1024 seconds
in 1 second increments.
:
www.artisancontrols.com
Universal Switch Adjustable
Interval Time Capsule
128
256
512
16
32
64
1
2
4
8
1
2
3
4
5
OPEN
6
7
8
®
9
®
10

Related parts for 438-USA-INT

438-USA-INT Summary of contents

Page 1

... Interval timing is adjustable from 1 to 1024 seconds in increments of 1 second. When voltage is applied, the 438USA-INT turns on permitting full load current to flow. At the end of the preset timing period the 438USA-INT turns off and permits only leakage current to flow through the load. To repeat a cycle, the operating voltage must be removed for at least 100 milliseconds ...

Page 2

... Four (4) #20 AWG wire six (6) inches long, Two (2) for operating voltage and two (2) for load circuit. January 31, 2006 The circuit shown illustrates how the 438USA-INT can be used to control the length of time that a starter motor circuit runs for only 10 seconds no matter how long the Motor Run switch is held closed. ...

Related keywords