G3MB-102-PL-DC24 Omron, G3MB-102-PL-DC24 Datasheet - Page 4

SSR, PCB MOUNT, 132VAC, 28.8VDC, 2A

G3MB-102-PL-DC24

Manufacturer Part Number
G3MB-102-PL-DC24
Description
SSR, PCB MOUNT, 132VAC, 28.8VDC, 2A
Manufacturer
Omron
Datasheet

Specifications of G3MB-102-PL-DC24

Control Voltage Type
DC
Input Voltage
19.2VDC To 28.8VDC
Load Current
2A
Load Voltage Range
75VAC To 132VAC
Switching Mode
Random
Relay Terminals
Through Hole
Control Voltage (nominal)
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
■ Approvals
UL Recognized (File No. E64562) - - Ambient Temp. = 40°C
CSA Certified (File No. LR35535)
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
Precautions
See General Information Section near the back of this catalog for
Solid State Precautions.
Make sure that the space between the bottom of the relay and the
PCB is 0.1 mm or less. When making holes on the PCB for the
relay’s edge terminals, the hole diameters should be slightly smaller
than the actual diameters of the edge terminals. This will reduce
unnecessary space between the bottom of the relay and the PCB.
To use the SSR output for phase control, select a model that does
not incorporate a zero-cross function.
The SSR case serves to dissipate heat. When mounting more than
three SSRs as a group, pay attention to the ambient temperature rise
and install the Relays so that they are adequately ventilated. If poor
ventilation is unavoidable, reduce the load current by half.
386
G3MB-102P
G3MB-202P
G3MB-202PL
G3MB-202PEG
G3MB-202PLEG
G3MB-102P
G3MB-202P
G3MB-202PL
SSR Type
SSR Type
2. In the interest of product improvement, specifications are subject to change.
individually defined in this catalog.
Solid State Relay
5 to 24 VDC
5 to 24 VDC
Input voltage
Input voltage
G3MB
General purpose
Tungsten
Motor
General purpose
Tungsten
Motor
General purpose
Tungsten
Motor
General purpose
Tungsten
Motor
Load type
Load type
DISCONTINUED
2 A, 120 VAC
1 A, 120 VAC
1.60 FLA/9.60 LRA, 120 VAC
2 A, 240 VAC
1 A, 240 VAC
1.60 FLA/9.60 LRA, 240 VAC
2 A, 120 VAC
1 A, 120 VAC
1.60 FLA/8.60 LRA, 120 VAC
2 A, 240 VAC
1 A, 240 VAC
1.60 FLA/8.60 LRA, 240 VAC
Protective Component
The input circuitry does not incorporate a circuit protecting the SSR
from being damaged due to a reversed connection. Make sure that
the polarity is correct when connecting the input lines.
Protective Element
No overvoltage absorption element is built in. Therefore, if the G3MB
is connected to an inductive load, be sure to connect the overvoltage
absorption element.