LSZ3B Honeywell Sensing and Control, LSZ3B Datasheet

no-image

LSZ3B

Manufacturer Part Number
LSZ3B
Description
Switch Actuator
Manufacturer
Honeywell Sensing and Control
Datasheet

Specifications of LSZ3B

For Use With
HDLS Series Heavy Duty Limit Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Double-Pole - Non Plug-In Type
Dimensions shown are for reference only.
All Heavy Duty Limit Switches (HDLS) have ex-
To mount either switch, merely tighten mounting
Single-Pole - Plug-in Type
Installation Instructions for
Heavy Duty Limit Switches
MOUNTING
actly the same mounting dimensions. Mount by
either of two methods: (a) use two #10 screws
from the front, or (b) use two #10-32 UNF screws
from the back. HDLS offers the advantage of
front mount construction. The electrician will find
a complete switch, with no parts missing and
ample wiring space.
W ith plug-in construction, wiring and conduit
connection is made to the base receptacle. This
feature also reduces downtime, since plug-in unit
can be removed without disconnecting wiring or
conduit.
screws, tighten plug-in unit or cover screws, and
make sure conduit section is sealed. Use of
sealant (teflon tape, pipe dope, etc.) is
down or at the low point of conduit runs.
recommended to seal conduit connection.
Because of moisture condensation problems, it is
not good practice to mount the switch upside
Key: 0,0 = mm
0.00 = in.
WlRlNG
smaller solid or stranded
wire to connect to the
Use size #12AWG or
pressure type connector
terminals. Spades may be
up to .312" wide, rings up
to .312" dia. With spade
or ring type connections,
preinsulated connectors
or heat-shrinkable tubing
should be used to provide
insulation between
terminals. Circuit diagram
connecting lead wires to the terminals nearest the
conduit opening first. A grounding screw is
order. Wires can be unsoldered and reconnected
is shown on the
nameplate.
It will be easier to wire the double-pole units by
located in the housing near the conduit opening.
Switch units with an indicator light in the cover
are furnished with the lead wires from the light
connected to the normally-open male terminals
(#3 and #4) unless otherwise specified on the
to the normally-closed male terminals or they can
be ordered connected to the normally-closed
terminals by using a modification code (refer to
Catalog 40). Always connect these wires to the
same set of terminals used for the load. Across
the normally open male terminals (#3 and #4) the
closed terminals (#1 and #2) the light will be Off.
Actuator Head. For
application flexibility,
actuator head may be
directions. Loosen the
four captive head
screws, place head in
the desired position, and
light will be On (Fig. 1). Across the normally-
positioned in any of four
then securely tighten the
four screws.
Reversing
roller levers, the roller arm may be reversed to
face the roller to the inside or outside of the arm.
ADJUSTING INSTRUCTIONS
the
roller
lever. Except for the offset
PK 81116
Figure 1

Related parts for LSZ3B

LSZ3B Summary of contents

Page 1

... Installation Instructions for Heavy Duty Limit Switches MOUNTING All Heavy Duty Limit Switches (HDLS) have ex- actly the same mounting dimensions. Mount by either of two methods: (a) use two #10 screws from the front, or (b) use two #10-32 UNF screws from the back. HDLS offers the advantage of front mount construction ...

Page 2

... Heavy Duty Limit Switches Positioning Lever. Lever on rotary actuated units is adjustable through 360° around the shaft. Loosen the screw with a 9/64 inch hexagon key wrench, move lever to desired position and securely tighten the screw until "teller tab" can no Ionger be moved by hand. ...

Page 3

... LSZ3J LSF3K LSZ3B LSF4L LSZ1H LSZ3A LSG3K LSZ1H LSZ3J LSH3K LSZ1H LSZ3B LSH4L LSZ1JGA LSZ3A LSJ3K-7A LSZ1JGM LSZ3A LSJ3K-7M LSZ3B LSJ4L-7A LSZ3B LSJ4L-7M LSZ1KHA LSZ3A LSK3K-8A LSZ1KHA LSZ3B LSK4L-8A LSZ1L LSZ3C LSL4M LSZ1M LSZ3C LSZ1N ** LSM4N LSN3K LSZ1N ** LSN4L LSZ1P LSZ3A ...

Page 4

... LSYAC1A LSZ7YAC1A LSA4001 PROPER APPLICATION OF LIMIT SWITCHES To achieve greatest reliability and longest life possible, limit switches should be installed as outlined in NEMA lCS2-225. For limit switches with pushrod actuators, appIy actuating force as nearly as possible in line with pushrod axis. PK 81116 891 Printed in USA GRAVlTY RETURN HDLS Listings beginning with LSS are gravity return devices ...

Related keywords