LSZ3B Honeywell Sensing and Control, LSZ3B Datasheet
LSZ3B
Specifications of LSZ3B
Related parts for LSZ3B
LSZ3B Summary of contents
Page 1
... Installation Instructions for Heavy Duty Limit Switches MOUNTING All Heavy Duty Limit Switches (HDLS) have ex- actly the same mounting dimensions. Mount by either of two methods: (a) use two #10 screws from the front, or (b) use two #10-32 UNF screws from the back. HDLS offers the advantage of front mount construction ...
Page 2
... Heavy Duty Limit Switches Positioning Lever. Lever on rotary actuated units is adjustable through 360° around the shaft. Loosen the screw with a 9/64 inch hexagon key wrench, move lever to desired position and securely tighten the screw until "teller tab" can no Ionger be moved by hand. ...
Page 3
... LSZ3J LSF3K LSZ3B LSF4L LSZ1H LSZ3A LSG3K LSZ1H LSZ3J LSH3K LSZ1H LSZ3B LSH4L LSZ1JGA LSZ3A LSJ3K-7A LSZ1JGM LSZ3A LSJ3K-7M LSZ3B LSJ4L-7A LSZ3B LSJ4L-7M LSZ1KHA LSZ3A LSK3K-8A LSZ1KHA LSZ3B LSK4L-8A LSZ1L LSZ3C LSL4M LSZ1M LSZ3C LSZ1N ** LSM4N LSN3K LSZ1N ** LSN4L LSZ1P LSZ3A ...
Page 4
... LSYAC1A LSZ7YAC1A LSA4001 PROPER APPLICATION OF LIMIT SWITCHES To achieve greatest reliability and longest life possible, limit switches should be installed as outlined in NEMA lCS2-225. For limit switches with pushrod actuators, appIy actuating force as nearly as possible in line with pushrod axis. PK 81116 891 Printed in USA GRAVlTY RETURN HDLS Listings beginning with LSS are gravity return devices ...