MLX90215EVA Melexis Inc, MLX90215EVA Datasheet - Page 44

IC SENSOR PROG LINEAR HALL 4SIP

MLX90215EVA

Manufacturer Part Number
MLX90215EVA
Description
IC SENSOR PROG LINEAR HALL 4SIP
Manufacturer
Melexis Inc
Type
Linear - Programmabler
Datasheets

Specifications of MLX90215EVA

Sensing Range
Unlimited
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
6.5mA
Current - Output (max)
2mA
Output Type
Analog, Ratiometric
Features
Regulated Voltage
Operating Temperature
-40°C ~ 85°C
Package / Case
4-SIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
90215DB106

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MLX90215EVA
Manufacturer:
MELEXIS
Quantity:
5 000
in section 4 of this book.
The figures above illustrate to performance of an unconditioned sensor output and a conditioned sensor output
versus stimulus(pressure) and temperature. Notice that figure XXa has a range of only 200mV and has a non-lin-
ear response over a 0-100psi range. The sensitivity of the unconditioned output will also drift over temperature,
as illustrated by the three slopes. The MLX90308 corrects thes errors and also amplifies the output to a more
usable voltage range as shown in figure XXb.
Prototyping with the MLX90308
Melexis has available a MLX90308 evaluation kit
which contains an evaluation circuit board, serial
interface cable, and software diskette. The circuit
board provides the neccessary circuitry for all three
applications circuits shown in the MLX90308
datasheet (section 4 of this book). Also contained on
theboard is level shifting and glue logic necessary
for RS-232 communicatios.
The boaerd has a socket with a single MLX90308
installed, and direct access to the pins of the IC. The
user can easily attach bridge sensor to the board for
in-system evaluation. The serial interface cable
connects the evaluation board directly to a PC’s ser-
ial port for in-system calibration.
The software runs in the familiar Windows platform
and allows for programming and evalution of all
compensation parameters within the EEPROM of
the MLX90308.
200
0
Figure 30a
Raw Sensor Output
measured between VBP and VBN
0
Hall
Plate
Pressure (in psi)
option is Current Mode, which allows the user a 4mA to 20mA current range to use as a
2-wire analog sensor. These wiring examples as well as technical specifications are shown
100
150
-40
25
o
o
o
C
C
C
5
0
Conditioned Sensor Output
measured between VMO and GND
Figure 30b
0
Pressure (in psi)
100
150
-40
25
o
o
o
C
C
C

Related parts for MLX90215EVA