E52-THE6F-100/200C Omron, E52-THE6F-100/200C Datasheet - Page 16

no-image

E52-THE6F-100/200C

Manufacturer Part Number
E52-THE6F-100/200C
Description
THERMISTOR SENSOR
Manufacturer
Omron
Series
E52r
Datasheet

Specifications of E52-THE6F-100/200C

Mounting Type
Free Hanging
Package / Case
Probe
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Resistance In Ohms @ 25°c
-
Resistance Tolerance
-
B Value Tolerance
-
B0/50
-
B25/50
-
B25/75
-
B25/85
-
B25/100
-
Operating Temperature
-
Power - Max
-
Lead Length
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E52THE6F100200C
Enclosed-terminal Models (High-temperature Use)
E52-PR@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Model Information
Note: The permissible temperature given for the protective tubing is
90
R (See
note 1.)
R (See
note 2.)
Note 1:
JIS ceramic Cat.1
(PT1)
Note 2:
JIS special ceramic
(PT0)
Element
Cap
type
G
rubber bushing built-in)
1
higher than 1,400°C, but the permissible temperature of the
thermocouple element wire is only 1,400°C. Therefore, the
protective tubing of the E52-PR@C can withstand high
temperatures momentarily to the levels given in the table as
exceptions, but the element wire will deteriorate quickly if the
thermocouple is used regularly at temperatures that exceed the
permissible temperature for the element wire.
/
2
Standard
, 15-A ground (with 11-inner-dia.
Enclosed-ter-
minal Models
Enclosed-ter-
minal Models
Terminal
98
type
57
Mullite, high
alumina, etc.
Recrystallized
alumina, fused
alumina, etc.
Protective tubing
50
75
100
50
75
100
Protective
material
length L
40 dia.
tubing
(cm)
Aluminum die-cast terminal box
100
E52-PR50C D=17 PT1
E52-PR75C D=17 PT1
E52-PR100C D=17 PT1
E52-PR50C D=17 PT0
E52-PR75C D=17 PT0
E52-PR100C D=17 PT0
21.7 dia.
1,500°C (See note.)
1,700°C (See note.)
Protective tubing
diameter D (mm)
temperature in dry
SUS304
Permissible
17 dia.
Model
air
Use wiring terminals that fit M4 screws.
Ceramic protective tubing (t2.0)
L-150
Bending of protective
tubing: 6 mm max.
17 dia.
Permissible Temperature in Dry Air
Terminal box: The permissible temperature
is 0°C to 80°C.
Note: The terminals in the cap indicate
17 dia.
polarity (+ or −).
D
0°C to 1,400°C
Element wire
R
E52
16

Related parts for E52-THE6F-100/200C