B59901D60A40 EPCOS Inc, B59901D60A40 Datasheet - Page 6

THERMISTOR PTC 100OHM 60DEG PROB

B59901D60A40

Manufacturer Part Number
B59901D60A40
Description
THERMISTOR PTC 100OHM 60DEG PROB
Manufacturer
EPCOS Inc
Series
B59901r
Type
PTCr
Datasheet

Specifications of B59901D60A40

Resistance In Ohms @ 25°c
100
Operating Temperature
90°C ~ 130°C
Mounting Type
PCB, Through Hole
Package / Case
Radial
Tolerance
25 %
Voltage
30 V
Thermistor Type
PTC
Resistance
570ohm
Operating Temperature Range
0°C To +40°C
Operating Voltage Range
30V
No. Of Pins
2
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Resistance Tolerance
-
Power - Max
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
B59901D 60A 40
B59901D0060A040
Mounting
Operation
Please read Cautions and warnings and
Important notes at the end of this document.
Sensors
Limit temperature sensors, probe assemblies
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-
pecially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Page 6 of 9
D901