XA1E-BV4U02-R IDEC, XA1E-BV4U02-R Datasheet - Page 4

SWITCH, EMERGENCY STOP, 2NC, 250VAC

XA1E-BV4U02-R

Manufacturer Part Number
XA1E-BV4U02-R
Description
SWITCH, EMERGENCY STOP, 2NC, 250VAC
Manufacturer
IDEC
Datasheet

Specifications of XA1E-BV4U02-R

Contact Configuration
DPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Current Max
5A
Actuator Style
Mushroom
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications and other descriptions in this catalog are subject to change without notice.
www.idec.com
Nameplate
Accessories
Panel Mounting
Remove the locking ring from the operator
and check that the gasket is in place. Insert
the operator from panel front into the panel
hole. Face the side with a projection upward,
and tighten the locking ring.
Using ring wrench MT-001, tighten the locking
ring to a torque of 0.88 N·m. Do not use pli-
ers. Do not apply excessive force, otherwise
the locking ring will be damaged.
For ø29mm
Mushroom
For ø40mm
Mushroom
Ring Wrench
ø16
Description
See “When using a nameplate” in Instructions below.
SEMI S2-compliant switch guard (XA9Z-KG1) and EMO label (HW9Z-EMO-NPP) are also available.
Turn off power to the XA series emergency stop switch before
installation, removal, wiring, maintenance, and inspection of the
switches. Failure to turn power off may cause electrical shocks or fire
hazard.
Notes for Panel Mounting
Instructions
Gasket
Safety Precautions
Shape
XA
Blank
EMERGENCY STOP HAAV-27
Blank
EMERGENCY STOP HAAV4-27
Locking Ring
Series
Legend
Operator
IDEC CORPORATION (USA)
1175 Elko Drive, Sunnyvale, CA 94089-2209, USA
Tel: +1-408-747-0550 / (800) 262-IDEC (4332)
Fax: +1-408-744-9055 / (800) 635-6246
E-mail: opencontact@idec.com
IDEC CANADA LIMITED
3155 Pepper Mill Court, Unit 4, Mississauga,
Ontario, L5L 4X7, Canada
Tel: +1-905-890-8561, Toll Free: (888) 317-4332
Fax: +1-905-890-8562
E-mail: sales@ca.idec.com
IDEC AUSTRALIA PTY. LTD.
2/3 Macro Court, Rowville, Victoria 3178, Australia
Tel: +61-3-9763-3244, Toll Free: 1800-68-4332
Fax: +61-3-9763-3255
E-mail: sales@au.idec.com
IDEC ELECTRONICS LIMITED
Unit 2, Beechwood, Chineham Business Park,
Basingstoke, Hampshire RG24 8WA, UK
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: sales@uk.idec.com
Projection
Emergency Stop Switches (Unibody Type)
Metal
(nickel-plated brass)
HAAV-0
HAAV4-0
Material
Part No.
Wiring
1.
2.
3.
4.
5.
6.
Use #110 receptacles for 0.5mm-thick tabs.
Because the terminal spacing is narrow, use
protective tubes or heat shrinkable tubes of
0.5mm minimum in thickness.
The applicable wire size is 1.25 mm
mum.
Solder the terminals using a soldering iron
at 310 to 350°C for 3 seconds. Make sure
that the soldering iron touches the termi-
nals only, not plastic parts. When wiring, do
not apply external force such as bending
the terminals or applying tensile force on
the wires.
Use a non-corrosive rosin flux.
Because the terminal spacing is narrow,
use protective tubes or heat shrinkable
tubes to avoid burning wire insulation or
short circuit.
Solder/Tab Terminal #110
Do not apply force on the terminals in the
direction other than vertical to the mounting
panel, otherwise the terminals will be dam-
aged.
For ø29mm Mushroom
MT-001
Part No.
IDEC ELEKTROTECHNIK GmbH
Wendenstrasse 331, 20537 Hamburg, Germany
Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24
E-mail: service@idec.de
IDEC (SHANGHAI) CORPORATION
Room 608-609, 6F, Gangtai Plaza, No. 700,
Yan'an East Road, Shanghai 200001, PRC
Tel: +86-21-5353-1000, Fax: +86-21-5353-1263
E-mail: idec@cn.idec.com
IDEC (BEIJING) CORPORATION
Room 211B, Tower B, The Grand Pacific Building,
8A Guanghua Road, Chaoyang District,
Beijing 100026, PRC
Tel: +86-10-6581-6131, Fax: +86-10-6581-5119
IDEC (SHENZHEN) CORPORATION
Unit AB-3B2, Tian Xiang Building, Tian’an Cyber Park,
Fu Tian District, Shenzhen, Guang Dong 518040, PRC
Tel: +86-755-8356-2977, Fax: +86-755-8356-2944
1.7
For wiring, use wires of a proper size to meet voltage and current
requirements and solder correctly. Failure to solder correctly may
cause overheating and fire.
7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
E-mail: products@idec.co.jp
Package Quantity
Cat. No. XA9Y-DS200-0 (Revised in USA 01/09 - PDF only)
Dimensions
0.3
For ø40mm Mushroom
2
maxi-
1
Contact Bounce
When the button is reset by pulling or turning,
the NC contacts will bounce. When designing
a control circuit, take the contact bounce time
into consideration (reference valu e: 20 ms).
Nameplate
Remove the
projection from the
nameplate using
pliers, otherwise
the switch cannot
be installed.
Handling
Do not expose the
switch to excessive
shock and vibrations,
otherwise the switch
may be deformed or
damaged, causing
malfunction or opera-
tion failure.
Used to ltighten the locking ring when
installing the XA switch onto a panel.
TIghtening torque: 0.88 N·m maximum
IDEC IZUMI (H.K.) CO., LTD.
Units 11-15, Level 27, Tower 1,
Millennium City 1, 388 Kwun Tong Road,
Kwun Tong, Kowloon, Hong Kong
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: info@hk.idec.com
IDEC TAIWAN CORPORATION
8F-1, No. 79, Hsin Tai Wu Road, Sec. 1,
Hsi-Chih, Taipei County, Taiwan
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: service@tw.idec.com
IDEC IZUMI ASIA PTE. LTD.
No. 31, Tannery Lane #05-01,
HB Centre 2, Singapore 347788
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: info@sg.idec.com
1.7
0.5
Remarks
Mounting panel
thickness: 0.5 to 3 mm
Material: Polyamide
Nameplate color: yellow
Legend color: black
Remarks
Projection
Nameplate

Related parts for XA1E-BV4U02-R