XA1E-BV4U02-N IDEC, XA1E-BV4U02-N Datasheet - Page 2

SWITCH, EMERGENCY STOP, 2NC, 250VAC

XA1E-BV4U02-N

Manufacturer Part Number
XA1E-BV4U02-N
Description
SWITCH, EMERGENCY STOP, 2NC, 250VAC
Manufacturer
IDEC
Datasheet

Specifications of XA1E-BV4U02-N

Contact Configuration
DPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Current Max
5A
Actuator Style
Mushroom
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Small, unibody emergency stop switches suitable for equipment with small mounting space.
Requires only ø16mm × 19.5mm for installation.
Standards
Note: Except for stop switches (operator color: yellow and gray)
Contact Ratings
2
UL508
CSA C22.2 No.14
EN60947-5-5 (Note)
Rated Insulation Voltage (Ui)
Thermal Current (Ith)
Rated Operating Voltage (Ue)
Rated
Operating
Current
ø29mm and ø40mm mushroom operators
Degree of protection IP65 and IP40 (IEC 60529)
Emergency stop switch operators are available in
red (Munsell 5R4/12)
Stop switch operators come in yellow or gray
Gold-plated crossbar contacts
Push-to-lock, pull or turn-to-reset operator
UL, c-UL recognized. EN compliant.
Safety lock mechanism (IEC 60947-5-5, 6.2)
Direct opening action mechanism
(IEC 60947-5-5, 5.2, IEC60947-5-1, Annex K)
Minimum applicable load: 5V AC/DC, 1 mA (reference value)
(May vary depending on the operating conditions and load.)
The rated operating currents are measured at resistive/inductive loads as
specified in IEC 60947-5-1.
Standards
ø16
AC
50/60Hz
DC
XA
Resistive Load
(AC-12)
Inductive Load
(AC-15)
Resistive Load
(DC-12)
Inductive Load
(DC-13)
Mark
Series
UL/c-UL File No. E68961
TÜV SÜD
European Commission’s
Low Voltage Directive
30V
Organization/File No.
2A
1A
Emergency Stop Switches (Unibody Type)
0.22A
250V
125V
0.4A
5A
5A
3A
250V
1.5A
0.2A
0.1A
3A
Specifications
Note: Except for stop switches (operator color: yellow and gray)
Applicable Standards
Operating Temperature
Operating Humidity
Storage Temperature
Operating Force
Minimum Force Required
for Direct Opening Action
Minimum Operator Stroke
Required for Direct
Opening Action
Maximum Operator Stroke 4.5 mm
Contact Resistance
Insulation Resistance
Overvoltage Category
Impulse Withstand Voltage 2.5 kV
Pollution Degree
Operating Frequency
Shock Resistance
Vibration Resistance
Durability
Degree of Protection
Short-circuit Protection
Conditional Short-circuit
Current
Terminal Style
Recommended Tightening
Torque for Locking Ring
Applicable Wire Size
Terminal Soldering
Condition
Weight (approx.)
UL508, CSA C22.2 No.14
IEC 60947-5-1, EN 60947-5-1
IEC 60947-5-5 (Note), EN 60947-5-5 (Note)
JIS C8201-5-1
−25 to +60°C (no freezing)
45 to 85% RH (no condensation)
−45 to +80°C (no freezing)
Push-to-lock: 10.5N
Pull to reset: 10N
Turn to reset: 0.16 N·m
40N
4.0 mm
50 mΩ maximum (initial value)
100 MΩ minimum (500V DC megger)
II
3
900 operations/hour
Operating extremes: 150 m/s
Damage limits:
Operating extremes: 10 to 500 Hz,
amplitude 0.35mm, acceleration 50 m/s
Damage limits:
amplitude 0.35 mm, acceleration 50 m/s
Mechanical: 250,000
Electrical:
IP65, IP40 (IEC 60529)
250V/10A fuse
(Type aM IEC 60269-1/IEC 60269-2)
1000A
Solder terminal, Solder/tab #110 terminal
0.88 N·m
1.25 mm
310 to 350°C, within 3 seconds
ø29mm mushroom: 14g
ø40mm mushroom: 17g
Solder Terminal
IP65 Type
(body color: yellow)
2
maximum (AWG16 maximum)
100,000
250,000 (24V AC/DC, 100mA)
1000 m/s
10 to 500 Hz,
Solder Terminal
IP40 Type
(body color: black)
Solder/tab #110
2
2
2
2

Related parts for XA1E-BV4U02-N