P2CF-11 Omron, P2CF-11 Datasheet

11 PIN Socket

P2CF-11

Manufacturer Part Number
P2CF-11
Description
11 PIN Socket
Manufacturer
Omron
Type
Socketr
Datasheets

Specifications of P2CF-11

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Accessory Type
Socket
Rohs Compliant
Yes
Associated Relay Series
H5CL
Number Of Poles
11
Mounting Style
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
P2CF11
Z884
DIN 48 × 48-mm Twin Timers
• Wide power supply ranges of 100 to 240 VAC and 48 to
• ON- and OFF-times can be set independently and so
• Fourteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h
• Models with a flicker ON start or flicker OFF start are available.
• Easy sequence checks through instantaneous outputs for a
• Length, when panel-mounted with a Socket, of 80 mm or less.
• 11-pin and 8-pin models are available.
Model Number Structure
■ Model Number Legend
Ordering Information
■ List of Models
1. Classification
F:
2. Configuration
None: 11-pin socket
8:
Note: Specify both the model number and supply voltage when ordering.
Flicker OFF
start
Flicker ON start 100 to 240 VAC
H3CR - F @ @ - @ @
125 VDC respectively.
combinations of long ON- or OFF-time and short OFF- or ON-
time settings are possible.
depending on the model to be used.
zero set value at any time range.
Solid-state Twin Timers
H3CR-F
Operating
modes
Example: H3CR-F 100-240AC
Twin timers
8-pin socket
1 2
100 to 240 VAC
24 VAC/DC
12 VDC
48 to 125 VDC
24 VAC/DC
12 VDC
48 to 125 VDC
http://www.ia.omron.com/
3
voltage
Supply
4
5
H3CR-F 100-240AC
H3CR-F 24AC/DC
H3CR-F 12DC
H3CR-F 48-125DC
H3CR-FN 100-240AC
H3CR-FN 24AC/DC
H3CR-FN 12DC
H3CR-FN 48-125DC
3. Twin Timer Mode
None: Flicker OFF start
N:
4. Time Range
None: 0.05 s to 30 h models
300:
11-pin models
Supply voltage
Flicker ON start
1.2 s to 300 h models
0.05 s to 30 h models
H3CR-F8 100-240AC
H3CR-F8 24AC/DC
H3CR-F8 12DC
H3CR-F8 48-125DC
H3CR-F8N 100-240AC
H3CR-F8N 24AC/DC
H3CR-F8N 12DC
H3CR-F8N 48-125DC
8-pin models
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
5. Supply Voltage
100-240AC: 100 to 240 VAC
24AC/DC:
12DC:
48-125DC: 48 to 125 VDC
H3CR-F-300 100-240AC
H3CR-F-300 24AC/DC
H3CR-F-300 12DC
H3CR-F-300 48-125DC
H3CR-FN-300 100-240AC
H3CR-FN-300 24AC/DC
H3CR-FN-300 12DC
H3CR-FN-300 48-125DC
11-pin models
24 VAC/VDC
12 VDC
1.2 s to 300 h models
H3CR-F8-300 100-240AC
H3CR-F8-300 24AC/DC
H3CR-F8-300 12DC
H3CR-F8-300 48-125DC
H3CR-F8N-300 100-240AC
H3CR-F8N-300 24AC/DC
H3CR-F8N-300 12DC
H3CR-F8N-300 48-125DC
8-pin models
1

Related parts for P2CF-11

P2CF-11 Summary of contents

Page 1

... H3CR-F-300 48-125DC H3CR-F8N 100-240AC H3CR-FN-300 100-240AC H3CR-F8N 24AC/DC H3CR-FN-300 24AC/DC H3CR-F8N 12DC H3CR-FN-300 12DC H3CR-F8N 48-125DC H3CR-FN-300 48-125DC (c)Copyright OMRON Corporation 2007 All Rights Reserved. 24 VAC/VDC 12 VDC 1 300 h models 11-pin models 8-pin models H3CR-F8-300 100-240AC H3CR-F8-300 24AC/DC H3CR-F8-300 12DC H3CR-F8-300 48-125DC ...

Page 2

... Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. http://www.ia.omron.com/ Y92F-30 Y92F-73 Y92F-74 PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P2CF-11 P2CF-11-E P3G-08 P3G-08 with Y92A-48G (See note 1) P3GA-11 P3GA-11 with Y92A-48G (See note 1) Y92H-7 Y92H-8 H3CR-F8 H3CR-FN Flicker ON start 8-pin 11-pin ×10 s (10 sec) min (min) 1 ...

Page 3

... EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4- contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level 3) IEC61000-4- power-line (level I/O signal-line (level 4) IEC61000-4- line to line (level line to ground (level 3) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 3 ...

Page 4

... OFF indicator detection circuit Indicator circuit ROM RAM Clock One-chip microcomputer H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F Output circuit Time range/unit selectors (+)(~) 4 ...

Page 5

... For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display window ON-time unit selector (select one from sec min, and hrs, or from min, hrs, and 10 h) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 0.1 s min OFF OFF ...

Page 6

... P2CF-11 P2CF-11-E * These dimensions vary with the kind of DIN track (reference value). ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. ...

Page 7

... Supply voltage 100 to 120 VAC H3CR-G8L 100-120AC 200 to 240 VAC H3CR-G8L 200-240AC 100 to 120 VAC H3CR-G8EL 100-120AC 200 to 240 VAC H3CR-G8EL 200-240AC (c)Copyright OMRON Corporation 2007 All Rights Reserved. 5. Supply Voltage 100-120AC: 100 to 120 VAC 200-240AC: 200 to 240 VAC 8-pin models 7 ...

Page 8

... Star-delta transfer time Programmable at 0.05 s, 0 0.5 s http://www.ia.omron.com/ Y92F-30 Y92F-70 Y92F-71 PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P3G-08 P3G-08 with Y92A-48G (See note 1) Y92S-27 Y92S-28 Y92P-48GL Y92P-48GB Y92P-48GM Y92H-1 Y92H-2 H3CR-G8L Star-delta timer with instantaneous output Time-limit: Instantaneous: SPST-NO (c)Copyright OMRON Corporation 2007 All Rights Reserved ...

Page 9

... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: IEC61000-4-4: IEC61000-4-5: (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level power-line (level I/O signal-line (level 4) ...

Page 10

... Star Star-delta Star-delta operation transfer time transfer time time counting oscillation counting circuit circuit circuit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Star operation Output circuit Delta operation Star operation indicator Indicator circuit Delta operation indicator Star operation ...

Page 11

... OFF ON OFF t1 ON OFF ON OFF Lit Not lit Lit Not lit Star-delta transfer time display window (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Star Delta operation operation contact contact them as relay terminals. 0.5 s min. t2 Time unit display (sec is fixed) Time setting knob (for setting ...

Page 12

... Dimensions with Front Connecting Socket P2CF-08-@ H3CR-G8@L 101.3* P2CF-08 P2CF-08-E * These dimensions vary with the kind of DIN track (reference value). ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. ...

Page 13

... H3CR-HRL 200-240AC M H3CR-HRL 24AC/DC M H3CR-HRL 48DC M H3CR-HRL 100-125DC M H3CR-H8RL 100-120AC S --- H3CR-H8RL 200-240AC S H3CR-H8RL 24AC/DC S H3CR-H8RL 48DC S H3CR-H8RL 100-125DC S Time range Supply voltage (c)Copyright OMRON Corporation 2007 All Rights Reserved. 6. Time Range min M-series 11-pin models 8-pin models H3CR-H8L 100-120AC M H3CR-H8L 200-240AC M ...

Page 14

... Y92F-30 Y92F-70 Y92F-71 PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P2CF-11 P2CF-11-E P3G-08 P3G-08 with Y92A-48G (See note 1) P3GA-11 P3GA-11 with Y92A-48G (See note 1) Y92H-1 Y92H-2 H3CR-H8L H3CR-H8RL Instantaneous operation/Time-limit reset/Forced reset No-voltage Relay output (SPDT) S-series s (sec) (c)Copyright OMRON Corporation 2007 All Rights Reserved ...

Page 15

... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: IEC61000-4-4: IEC61000-4-5: (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level power-line (level I/O signal-line (level 4) ...

Page 16

... VDC for H3CR-H8RL (failure level: P). Time range/ unit selector Oscillation Counting Output circuit circuit circuit Indicator circuit Time range/ unit selector Oscillation Counting Output circuit circuit circuit Indicator circuit Input circuit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H Output indicator Output indicator 16 ...

Page 17

... With Reset Input (H3CR-HRL) Reset input Power supply Note: Leave terminal 6 open. Do not use them as relay terminals. http://www.ia.omron.com/ With Reset Input (H3CR-H8RL) Reset input Power supply Note: Leave terminal 3 open. Do not use them as relay terminals. (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H 17 ...

Page 18

... Output (8 − 5) Lit Output indicator Not lit Rt ON Power (See note) OFF 0.05 s min. Reset input Output (1 − 3) Output (1 − 4) Output (11 − 9) Output (11 − 8) Lit Output indicator Not lit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR 0.05 s min 0.05 s min. 18 ...

Page 19

... P3G-08/P3GA-11 92.9 15 86.4 H3CR-HRL 109.9 H3CR- H8@L P3G-08 Y92F-30 * P2CF-11 2.3 P2CF-11-E (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H Time setting knob (for setting power OFF-delay time) 78.0 0.7 44.8 × 44.8 8 pins 78.0 0.7 44.8 × 44.8 11 pins 92 ...

Page 20

... If the H3CR-H is dropped or experiences some other kind of shock, because a latching relay is used for output, contacts may be reversed or go into a neutral state. If the H3CR-H is dropped, reconfirm correct operation. Short-circuit current *: H3CR-H8RL (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR min min min. 20 ...

Page 21

... Normal operation may not be possible in locations subject to sulfidizing gas, such as in sewer systems or waste incinerators. OMRON does not market any Timers or other control devices for operation in atmospheres containing sulfidizing gas. Seal the Timer so that sulfidizing gas will not enter it. If sealing is not possible, OMRON does provide special Timers with improved resistance to sulfidizing gas ...

Page 22

... T X • Be sure that only a qualified worker (e.g., an electrical engineer) performs electrical work for the Timer. Incandescent lamp load times the rated current Mercury light loads times the rated load (c)Copyright OMRON Corporation 2007 All Rights Reserved. T Auxiliary relay (e.g., MY Relays) ...

Page 23

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...