Contact Data
Note: Contact your OMRON representative for the ratings on fully sealed models.
Maximum Switching Capacity
Standard models
PCB Relay
Number of poles
Contact materials
Contact resistance
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Mechanical endurance
Max operating frequency
Electrical endurance data C.O.:12 A at 250 VAC (cosφ=1)
Contact rating
(Approved Standards)
Values in the above table are the initial values.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information for the electrical endurance under
your test conditions.
G2RL-1A, G2RL-1
Switching voltage (V)
DC resistive
load
AC resistive load
1 pole
AgSnO
100 mΩ max.
12 A at 250 VAC
12 A at 24 VDC (See note.)
12 A (See note.)
440 VAC, 300 VDC
12 A
3,000 VA
20,000,000 operations (at 18,000 operations/hr)
Mechanical: 18,000 operation/hr
Electrical: 1,800 operation/hr at rated load
N.O. only:5 A at 250 VAC (cosφ=0.4)
UL508 (File No. E41643)/CSA C 22.2(No. 14) (File No. LR31928)
12 A at 250 VAC (General use)
12 A at 24 VDC (Resistive)
VDE (EN61810-1) (License No. 119650)
12 A at 250 VAC(cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
12 A at 24 VDC
2
(Cd free)
5 A at 30 VDC (L/R=7 ms)
50,000 operations min.
30,000 operations min.
150,000 operations min.
20,000 operations min.
G2RL-2A, G2RL-2
Standard models
Switching voltage (V)
2 pole
8 A at 250 VAC
8 A at 30 VDC (See Note.)
8 A (70°C)/5 A (85°C) (See note.)
8 A
2,000 VA
C.O.:8 A at 250 VAC (cosφ=1)
8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
8 A at 250 VAC (cosφ=1)
8 A at 24 VDC (L/R=0 ms)
AC15: 1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
DC resistive
load
8 A at 30 VDC
AC resistive load
30,000 operations min.
30,000 operations min.
High-capacity models
A Power Relay with Various Models
■
■
■
■
■
■
■
RoHS Compliant
High-sensitivity (250 mW) and High-capacity
(16 A) Models available.
Low profile: 15.7 mm max. in height
Conforms to VDE (EN61810-1), UL508 and
CSA22.2.
Meets EN60335-1 requirements for household
products.
Clearance and creepage distance: 10 mm/10 mm.
Tracking resistance: CTI>250
Coil Insulation system: Class F (UL1446)
G2RL-1A-E, G2RL-1-E
1 pole
16 A at 250 VAC
16 A at 30 VDC (See note.)
16 A (See note.)
16 A
4,000 VA
C.O.:16 A at 250 VAC (cosφ=1)
N.O. only:8 A at 250 VAC (cosφ=0.4)
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC (L/R=0 ms)
AC15:3 A at 240 VAC(NO),
DC13:2.5 A at 24 VDC(NO), 50 ms
Switching voltage (V)
16 A at 24 VDC
1.5 A at 240 VAC (NC)
16 A at 250 VAC (cosφ=1) at
105°C -CV type
High-capacity models
8 A at 30 VDC (L/R=7 ms)
Pilot duty (A300), 250 VAC
Pilot duty (A300), 125 VAC
16 A at 250 VAC (cosf=1) at 105×C
30,000 operations min.
30,000 operations min.
200,000 operations min.
10,000 operations min.
250,000 operations min.
150,000 operations min.
100,000 operations min. by -CV type.
DC resistive
load
AC resistive load
High-sensitivity models
1 pole
10 A at 250 VAC
10 A at 24 VDC (See note.)
10 A (See note.)
10 A
2,500 VA
C.O.:10 A at 250 VAC (cosφ=1)
10 A at 250 VAC (General use)
10 A at 24 VDC (Resistive)
10 A at 250 VAC(cosφ=1)
10 A at 24 VDC (L/R=0 ms)
G2RL-1A-H, G2RL-1-H
G2RL
High-sensitivity models
10 A at 24 VDC
100,000 operations min.
50,000 operations min.
Switching voltage (V)
DC resistive
load
AC resistive load
1