G2RL-1A-E-CV DC12 Omron, G2RL-1A-E-CV DC12 Datasheet

RELAY, PCB, SPST-NO, 12VDC, 16A

G2RL-1A-E-CV DC12

Manufacturer Part Number
G2RL-1A-E-CV DC12
Description
RELAY, PCB, SPST-NO, 12VDC, 16A
Manufacturer
Omron
Datasheet

Specifications of G2RL-1A-E-CV DC12

Relay Type
Power
Coil Voltage Vdc Nom
12V
Contact Current Max
16A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Coil Resistance
360ohm
Coil Type
DC Coil, Sensitive
Coil Current
20.8mA
Contact Configuration
SPST-NO
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Contact Data
Note: Contact your OMRON representative for the ratings on fully sealed models.
Maximum Switching Capacity
Standard models
PCB Relay
Number of poles
Contact materials
Contact resistance
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Mechanical endurance
Max operating frequency
Electrical endurance data C.O.:12 A at 250 VAC (cosφ=1)
Contact rating
(Approved Standards)
Values in the above table are the initial values.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information for the electrical endurance under
your test conditions.
G2RL-1A, G2RL-1
Switching voltage (V)
DC resistive
load
AC resistive load
1 pole
AgSnO
100 mΩ max.
12 A at 250 VAC
12 A at 24 VDC (See note.)
12 A (See note.)
440 VAC, 300 VDC
12 A
3,000 VA
20,000,000 operations (at 18,000 operations/hr)
Mechanical: 18,000 operation/hr
Electrical: 1,800 operation/hr at rated load
N.O. only:5 A at 250 VAC (cosφ=0.4)
UL508 (File No. E41643)/CSA C 22.2(No. 14) (File No. LR31928)
12 A at 250 VAC (General use)
12 A at 24 VDC (Resistive)
VDE (EN61810-1) (License No. 119650)
12 A at 250 VAC(cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
12 A at 24 VDC
2
(Cd free)
5 A at 30 VDC (L/R=7 ms)
50,000 operations min.
30,000 operations min.
150,000 operations min.
20,000 operations min.
G2RL-2A, G2RL-2
Standard models
Switching voltage (V)
2 pole
8 A at 250 VAC
8 A at 30 VDC (See Note.)
8 A (70°C)/5 A (85°C) (See note.)
8 A
2,000 VA
C.O.:8 A at 250 VAC (cosφ=1)
8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
8 A at 250 VAC (cosφ=1)
8 A at 24 VDC (L/R=0 ms)
AC15: 1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
DC resistive
load
8 A at 30 VDC
AC resistive load
30,000 operations min.
30,000 operations min.
High-capacity models
A Power Relay with Various Models
RoHS Compliant
High-sensitivity (250 mW) and High-capacity
(16 A) Models available.
Low profile: 15.7 mm max. in height
Conforms to VDE (EN61810-1), UL508 and
CSA22.2.
Meets EN60335-1 requirements for household
products.
Clearance and creepage distance: 10 mm/10 mm.
Tracking resistance: CTI>250
Coil Insulation system: Class F (UL1446)
G2RL-1A-E, G2RL-1-E
1 pole
16 A at 250 VAC
16 A at 30 VDC (See note.)
16 A (See note.)
16 A
4,000 VA
C.O.:16 A at 250 VAC (cosφ=1)
N.O. only:8 A at 250 VAC (cosφ=0.4)
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC (L/R=0 ms)
AC15:3 A at 240 VAC(NO),
DC13:2.5 A at 24 VDC(NO), 50 ms
Switching voltage (V)
16 A at 24 VDC
1.5 A at 240 VAC (NC)
16 A at 250 VAC (cosφ=1) at
105°C -CV type
High-capacity models
8 A at 30 VDC (L/R=7 ms)
Pilot duty (A300), 250 VAC
Pilot duty (A300), 125 VAC
16 A at 250 VAC (cosf=1) at 105×C
30,000 operations min.
30,000 operations min.
200,000 operations min.
10,000 operations min.
250,000 operations min.
150,000 operations min.
100,000 operations min. by -CV type.
DC resistive
load
AC resistive load
High-sensitivity models
1 pole
10 A at 250 VAC
10 A at 24 VDC (See note.)
10 A (See note.)
10 A
2,500 VA
C.O.:10 A at 250 VAC (cosφ=1)
10 A at 250 VAC (General use)
10 A at 24 VDC (Resistive)
10 A at 250 VAC(cosφ=1)
10 A at 24 VDC (L/R=0 ms)
G2RL-1A-H, G2RL-1-H
G2RL
High-sensitivity models
10 A at 24 VDC
100,000 operations min.
50,000 operations min.
Switching voltage (V)
DC resistive
load
AC resistive load
1

Related parts for G2RL-1A-E-CV DC12

G2RL-1A-E-CV DC12 Summary of contents

Page 1

... A at 250 VAC (General use VDC (Resistive 250 VAC(cosφ= VDC (L/R=0 ms) 1 240 VAC (NC 250 VAC (cosφ=1) at 105°C -CV type High-sensitivity models G2RL-1A-H, G2RL-1-H AC resistive load DC resistive load Switching voltage (V) AC resistive load DC resistive load 1 ...

Page 2

... Ambient Temperature Ambient Temperature vs Rated Carry Current vs Maximum Coil Voltage G2RL-1A-E, G2RL-1-E G2RL-1A, G2RL-1 G2RL-1A-H, G2RL-1-H G2RL-2A, G2RL-2 Ambient temperature (°C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Insulation Number of poles ...

Page 3

... G2RL-2A, G2RL-2A4 15.7 max. (15.5)* 0.5 3.5 G2RL-2, G2RL-24 15.7 max. (15.5)* 3.5 0.5 High-capacity models G2RL-1A-E, G2RL-1A4-E 15.7 max. (15.5)* 0.5 3.5 G2RL-1-E, G2RL-14-E 15.7 max. (15.5)* 3.5 0.5 Terminal Arrangement/ Internal Connection 12.7 max. (Bottom View) (12 ...

Page 4

... G2RL-1 Fully sealed G2RL-1A4 G2RL-14 Note: When ordering, add the rated coil voltage to the model number. Example: G2RL-1A 12 VDC Rated coil voltage Precautions Disclaimer: All technical performance data applies to the product as such; specific conditions of individual applications are not considered. Always check the suitability of the product for your intended purpose ...

Related keywords