G6K-2FY 12DC Omron, G6K-2FY 12DC Datasheet - Page 4

RELAY, SMD, DPCO, 12VDC

G6K-2FY 12DC

Manufacturer Part Number
G6K-2FY 12DC
Description
RELAY, SMD, DPCO, 12VDC
Manufacturer
Omron
Datasheet

Specifications of G6K-2FY 12DC

Coil Type
DC Coil, Monostable
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
12V
Coil Current
9.1mA
Coil Resistance
1.315kohm
Relay Mounting
PC
Contact Configuration
DPDT
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Life Expectancy
G6K
Engineering Data
4
Maximum Switching Power
Shock Malfunction
Shock direction
Conditions: Shock is applied in $X, $Y, and $Z
DC resistive load
125 VAC resistive load
Ambient temperature: 23#C
Switching frequency:
1,800 operations/hour
directions three times each with and
without energizing the Relays to check
the number of contact malfunctions.
30 VDC resistive load
Ambient temperature: 23#C
Switching frequency:
1,800 operations/hour
Switching current (A)
Switching voltage (V)
AC resistive load
Not
energized
Unit: m/s
Sample: G6K-2G
Number of Relays: 10
Energized
2
Note: The maximum coil voltage refers to the maxi-
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Maximum Coil Voltage
Electrical Life Expectancy
(with Must Operate and Must
Release Voltage) (see note)
G6K-2G (F/P), G6K-2G (F/P)-Y
mum value in a varying range of operating
power voltage, not a continuous voltage.
Operating frequency (x10
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Must operate
Must release
Ambient temperature (#C)
Ambient temperature (#C)
Max. estimated value
Must operate voltage
Must release voltage
3
operations)
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Ambient Temperature vs.
Switching Current
Electrical Life Expectancy
(Contact Resistance) (see note)
G6K-2G (F/P), G6K-2G (F/P)-Y
Operating frequency (x10
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Contact resistance
Ambient temperature (#C)
Ambient temperature (#C)
Max. estimated value
3
operations)
G6K
NO
contact
NC
contact

Related parts for G6K-2FY 12DC