LT4HW-AC240V PANASONIC EW, LT4HW-AC240V Datasheet

TIMER, TWIN, 11 PINS, 240VAC

LT4HW-AC240V

Manufacturer Part Number
LT4HW-AC240V
Description
TIMER, TWIN, 11 PINS, 240VAC
Manufacturer
PANASONIC EW
Datasheet

Specifications of LT4HW-AC240V

Contact Configuration
SPDT
Nom Input Voltage
240V
Delay Time Range
99.99s To 9999h
Adjustment Type
Pushbutton
Relay Mounting
Panel
Svhc
No SVHC (15-Dec-2010)
External Depth
65mm
External Length /
RoHS Compliant
LT4H-W
UL File No.: E122222
CSA File No.: LR39291
PRODUCT TYPES
* A rubber gasket (ATC18002) and a mounting frame (AT8-DA4) are included.
44
8 Pin type
1.890
99.99s
999.9s
9999s
99min59s
999.9min
99h59min
999.9h
9999h
48
Time range
11 Pin type Screw terminal
1.890
48
• Delayed one shot
• OFF-start flicker
• ON-start flicker
• Delayed one shot
• OFF-start flicker
• ON-start flicker
Integrating input:
Operation mode
2.539
64.5
Pulse input:
mm
type
inch
FEATURES
1. Wide time range
The operation time range covers from
0.01 sec. to 9999 hours.
The individual setting can be performed
on each of 1 and 2 timers.
99.99s 99min59s
999.9s 999min
9999s
2. Bright and Easy-to-Read Display
A brand new bright 2-color back light
LCD display. The easy-to-read screen in
any location makes checking and setting
procedures a cinch.
3. Simple Operation
Seesaw buttons make operating the unit
even easier than before.
4. Short Body of only 64.5 mm
inch
2.760 inch
With a short body, it is easy to install in
even narrow control panels.
DIN 48 SIZE
DIGITAL TIMER
Transistor
(screw terminal type) or 70.1 mm
Output
Relay
(1 c)
(1 a)
(pin type)
24 V AC / 24 V DC
24 V AC / 24 V DC
Operation voltage
100-240 V AC
100-240 V AC
12-24 V DC
12-24 V DC
02/2003
99h59min
999.9h
9999h
2.539
Power down insurance
Available
5. Conforms to IP66’s Weather
Resistant Standards
The water-proof panel keeps out water
and dirt for reliable operation even in
poor environments.
6. Screw terminal and Pin Type are
Both Standard Options
The two terminal types are standard
options to support either front panel
installation or embedded installation.
7. Changeable Panel Cover
Also offers a black panel cover to meet
your design considerations.
8. Conforms With EMC and Low
Voltage Directives
Conforms with EMC directives
(EN50081-2/EN50082-2) and low
-voltage directives (VDE0435/Part 2021)
for CE certification vital for use in
Europe.
9. Good performance
All this at an affordable price to provide
you with unmatched cost performance.
LT4H-W
Terminal
11 pin
Screw
11 pin
Screw
11 pin
Screw
11 pin
Screw
11 pin
Screw
11 pin
Screw
8 pin
8 pin
8 pin
8 pin
8 pin
8 pin
LT4HW8-AC240V
LT4HW-AC240V
LT4HW-AC240VS
LT4HW8-AC24V
LT4HW-AC24V
LT4HW-AC24VS
LT4HW8-DC24V
LT4HW-DC24V
LT4HW-DC24VS
LT4HWT8-AC240V
LT4HWT-AC240V
LT4HWT-AC240VS
LT4HWT8-AC24V
LT4HWT-AC24V
LT4HWT-AC24VS
LT4HWT8-DC24V
LT4HWT-DC24V
LT4HWT-DC24VS
Part No.

Related parts for LT4HW-AC240V

LT4HW-AC240V Summary of contents

Page 1

... CE certification vital for use in Europe. 9. Good performance All this at an affordable price to provide you with unmatched cost performance. Terminal Part No. 8 pin LT4HW8-AC240V 11 pin LT4HW-AC240V Screw LT4HW-AC240VS 8 pin LT4HW8-AC24V 11 pin LT4HW-AC24V Screw LT4HW-AC24VS 8 pin LT4HW8-DC24V 11 pin LT4HW-DC24V Screw LT4HW-DC24VS ...

Page 2

... Hz: 1 cycle/ min single amplitude of 0. Hz: 1 cycle/ min single amplitude of 0.75 mm Min 321.522 Min. 294 m 964.567 –10° 55° C 860 to 1,060 h Pa — less 8-pin/11-pin/screw terminal IP66 (front panel with rubber gasket) 02/2003 DIP switches Transistor output type AC type 1) 100 to 240V AC, 24V AC ...

Page 3

LT4H-W DIMENSIONS (units: mm inch) • LT4H-W digital timer 48 1.890 TIMER LT4H OP. T2 LOCK RESET SET/LOCK DOWN • Dimensions for embedded installation (with adapter installed) Screw-down terminal type installation panel Rubber ...

Page 4

... SETTING THE OPERATION MODE, TIMER RANGE, AND TIME Setting procedure 1) Setting the operation mode and timer range (Timer T Set the operation mode and timer range with the DIP switches on the side of the unit. DIP switches Item 1 Time range 2 (Timer Minimum input reset, signal, and ...

Page 5

LT4H-W PULSE PULSE A OFF-start/1 operation t Power supply A Output Delayed T1 T2 one shot Stop Reset Signal PULSE B OFF-start/repeating operation t Power supply B Output OFF-start flicker Stop Reset Signal PULSE C ON-start/repeating ...

Page 6

... V, the signal can be input without using an open collector transis- tor. In the case of the diagram below, when the non-contact point transistor Q switches from off to on (when the signal voltage goes from high to low), the sig- nal is input. DC12 to 40V Reset input ...

Page 7

... When using the other modes, control the timer with the signal input or stop input. 10) The operation mode and time range can be set with the DIP switches on the side of the timer. Make the DIP switch settings before installing the timer on the panel. ...