HXS 20-NP/SP30 LEM, HXS 20-NP/SP30 Datasheet
HXS 20-NP/SP30
Specifications of HXS 20-NP/SP30
Related parts for HXS 20-NP/SP30
HXS 20-NP/SP30 Summary of contents
Page 1
... Current Transducer HXS 20-NP/SP30 For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data I Primary nominal r.m.s. current PN I Primary current measuring range P V Analog output voltage @ I ...
Page 2
... Current Transducer HXS 20-NP/SP30 Insulation category V Nominal Voltage b with IEC 61010-1 standards and following conditions - Single insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field V Nominal Voltage b with EN 50178 standards and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 ...
Page 3
... HXS 20-NP/SP30 Dimensions (in mm) 0.6 Ref Out GND Vc 4-0.5*0.25 7.7 Number of primary turns Mechanical characteristics General tolerance Fastening & connection of primary jumper Recommended PCB hole Fastening & connection of secondary Recommended PCB hole LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. ...