SM91EANQD BANNER ENGINEERING, SM91EANQD Datasheet - Page 34

no-image

SM91EANQD

Manufacturer Part Number
SM91EANQD
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of SM91EANQD

Output Current
150mA
Sensor Output
NPN/PNP
Supply Voltage Range Dc
10V To 30V
Peak Reflow Compatible (260 C)
No
Sensor Input
Optical
Sensing Range Max
30m
Leaded Process Compatible
No
360
VALU-BEAM
Supply Voltage and Current
Output Configuration
Output Rating
Output Protection Circuitry
Output Response Time
Repeatability
Adjustments
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Certifications
®
SMI912 Series Sensors
CSA:
FM:
KEMA:
10 to 30V dc for sensor, 25 mA maximum
Division 1 use, with barriers, requires a minimum system supply voltage of 10V
Current sinking NPN open collector transistor
3-wire hookup sinks 15 mA maximum, continuous
2-wire hookup sinks 10 mA (OFF-state) and 20 mA (ON state)
Protected against false pulse on power-up and short circuit of output
4 milliseconds ON and OFF, except for opposed mode receivers, which are 8 ms ON, 4 ms OFF;
independent signal strength
(NOTE: 100 millisecond delay on power-up: output is non-conducting during this time)
Opposed: 1.0 millisecond; Retro, Diffuse, Convergent, Plastic and Glass Fiber Optic: 1.3 milliseconds
LIGHT/DARK OPERATE select switch on rear of sensor
Sensitivity control on rear of sensor allows precise gain setting (turn clockwise to increase gain)
Exclusive, patented Alignment Indicating Device (AID
LED indicator whenever the sensor sees a “light” condition, with a superimposed pulse rate proportional
to the light signal strength (the stronger the signal, the faster the pulse rate).
Reinforced thermoplastic polyester housing, totally encapsulated, molded acrylic lenses, stainless steel
hardware
Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12 and 13; IEC IP66
Supplied with 3-pin quick-disconnect (QD) fitting and requires the use of mating cable model SMICC-312. Cable is
not supplied with sensors. See page 368 and Accessories section.
Temperature:
Relative relative humidity: 90% at 50°C (non-condensing)
#LR 41887
#J.I. OR3HO.AX
#Ex-96.D.0950
Banner Engineering Corp. • Minneapolis, U.S.A. • www.bannerengineering.com • Tel: 763.544.3164
SMI912 Series Specifications
Exia
APPROVALS
-20° to +70°C (-4 to +158°F)
Instrinsically Safe, with Entity for:
Class I, Groups A-D
Class I, Div. 2, Groups A-D
Intrinsically Safe, with Entity for:
Class I, II, III, Div. 1, Groups A-G
Class I, II, III, Div. 2, Groups A-D and G
EEx ia IIC T6
, US patent #4356393) lights at top mounted red

Related parts for SM91EANQD