T18SP6FF100 BANNER ENGINEERING, T18SP6FF100 Datasheet - Page 4

no-image

T18SP6FF100

Manufacturer Part Number
T18SP6FF100
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of T18SP6FF100

Sensing Range
100mm
Output Current
150mA
Sensor Output
PNP
Supply Voltage Range Dc
10V To 30V
Sensor Input
Optical
Output Type
Transistor
Sensing Range Max
100mm
Contact Current Max
150mA
Brand/series
T18
Accessories Available
Cordsets, Brackets and Reflectors
4
Supply Voltage and
Current
Supply Protection
Circuitry
Output Configuration
Output Rating
Output Protection
Circuitry
Output Response Time
Repeatability
Adjustments
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Vibration and Mechanical
Shock
Certifications
P/N 121526 rev. A
T18 Sensors — dc-Voltage Series
10 to 30V dc (10% max. ripple); supply current (exclusive of load current):
Protected against reverse polarity and transient voltages
SPDT solid-state dc switch; NPN (current sinking) or PNP (current sourcing), depending on model
Light Operate: N.O. output conducts when sensor sees its own (or the emitter’s) modulated light
Dark Operate: N.C. output conducts when the sensor sees dark; the N.C. (normally closed) output may be wired as a
150 mA maximum (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp @ 30V dc
ON-state saturation voltage: < 1V @ 10 mA dc; < 1.5V @ 150 mA dc
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Opposed mode: 3 ms ON, 1.5 ms OFF
Retro, Fixed-Field and Diffuse: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this time.
Opposed mode: 375 µs
Retro, Fixed-Field and Diffuse: 750 µs
Repeatability and response are independent of signal strength.
Non-polarized retro and diffuse models (only) have a single-turn rear-panel Sensitivity control (turn clockwise to increase
gain).
Two LEDs (Green and Yellow)
Green ON steady: power to sensor is ON
Green flashing: output is overloaded
Yellow ON steady: N.O. output is conducting
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Temperature: −40° to +70° C (−40° to +158° F)
Maximum relative humidity: 90% at 50° C (non-condensing)
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude
0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
2 m (6.5') or 9 m (30') attached cable or 4-pin Euro-style quick-disconnect fitting
Emitters, Non-Polarized Retro, Diffuse: 25 mA
Receivers: 20 mA
Polarized Retroreflective: 30 mA
Fixed-Field: 35 mA
normally open marginal signal alarm output, depending upon hookup to power supply
Specifications
Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164

Related parts for T18SP6FF100