Printed in USA
LR300 & PT300
The LR300 emitter and PT300 receiver are compact, totally-encapsulated opposed mode remote sensors whose right-angle design, ex-
tremely small size, and excellent operating characteristics make them ideal for many sensing applications. Mounting and alignment are
very simple, due to these sensors' wide field of view. The LR300 and PT300 easily mount in place by means of their through-mounting
holes and two #4 screws.
"300" series sensors are fully encapsulated with hermetically sealed lenses to eliminate internal condensation, and have extremely flex-
ible, low-profile 2-wire cable. Units may be washed down without damage. Identical optical performance in different housing styles
is available in models LR/PT 200, 250, and 400 (see Banner product catalog).
The minimum object size required to break the beam of the LR300/PT300 opposed mode sensor pair is 1/8-inch. These sensors are
designed for use with Banner MICRO-AMP
modulated amplifiers, and MB Series amplifiers.
RANGE: up to 8 feet in opposed mode (see gain curve)
EFFECTIVE BEAM: 0.14 inch (3,6 mm) diameter
RESPONSE SPEED: a function of the amplifier (see below)
OPERATING TEMPERATURE: -40 to +80° C (-40 to +176° F)
EMITTER CHARACTERISTICS: infrared LED, 880nm
CONSTRUCTION: totally encapsulated, hermetically sealed lenses.
Valox
CABLE: sensors are supplied with 6' of low-profile 2-wire PVC-cov-
ered cable. 30' cables are available by special order.
Hookup to MB Series Amplifiers
Banner remote sensors will connect to any MB Series amplifier. The
model MRB chassis (shown) has octal sockets for the amplifier and a
BR-2 relay (supplied) and provides power for the sensors and ampli-
fier. Up to four sensor pairs may be connected to one amplifier for
light-operated OR or dark operated AND operation. In multiple-sensor
hookups, receivers are wired in parallel and emitters are connected in
series (see example for CM Series modules, next page).
Several MB Series amplifiers are available. Each provides a different
output logic function. Refer to the Banner catalog for more informa-
tion.
Chassis models with additional octal sockets are also available. Other
types of output devices, including solid state relays, may be ordered
(see Banner catalog).
OUTPUT CONFIGURATION: open collector NPN transistor; maximum
on-state current 250mA, maximum off-state leakage current 100 micro-
RESPONSE SPEED: 1 millisecond ON and OFF.
OPERATING TEMPERATURE RANGE: 0 to +50°C (+32 to +122° F).
Specifications, LR/PT300
Specifications, MB Series Amplifiers
POWER SUPPLY REQUIREMENT: 12-18V dc at less than 100mA,
exclusive of load.
MAXIMUM SENSOR LEAD LENGTH: 100 feet (30m) maximum;
use separate shielded cables for emitter and reciever.
®
housing; NEMA 1, 3, 4, 12, and 13.
®
system MA3-4 and MA3-4P modulated amplifiers, MAXI-AMP™ system CM Series
Opposed Mode
Remote Sensor Pair
Wiring rules:
1) Avoid running remote sensor cables in wireways together with
power-carrying conductors.
2) Avoid running remote sensor cables through areas of known ex-
treme electrical interference (electrical "noise").
3) Always use shielded cables and only connect the shield ("drain")
wire at the amplifier.
4) When splicing, never combine emitter and receiver wires into a
common cable. (The result will be electrical "crosstalk" within the
cable, which causes a "lock-on" condition of the amplifier.)
EXCESS GAIN CURVE
BEAM PATTERN
P/N 03472C4A