MLV14-55/49/82A/123/124 PEPPERL & FUCHS, MLV14-55/49/82A/123/124 Datasheet - Page 33

no-image

MLV14-55/49/82A/123/124

Manufacturer Part Number
MLV14-55/49/82A/123/124
Description
Photoelectric Sensor
Manufacturer
PEPPERL & FUCHS
Datasheet

Specifications of MLV14-55/49/82A/123/124

Sensor Input
Optical
Output Type
Transistor
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
3. Press the "+" and "-" buttons simultaneously for two
4. The "teach" mode is completed when the green LED
An optical interface (used with a PC or a hand-held
device) is used to set the optional "enhanced" parameters.
The factory settings are underlined. Optical interface
programming is not available for the MLV11-8-H series.
Please see pages 765-768 for more details on these
parameters and using the OPUS software or
handheld programmer.
Outputs
Optical failure control
Switching frequency/Response time
Hysteresis
Parameter Settings
seconds (until the green LED flashes) then release both
keys. The green LED will be flashing at 2 Hz which
indicates the sensor is in "teach" mode.
remains on.
PEPPERL+FUCHS
N.O. and failure output (weak signal output)
N.C. and failure output (weak signal output)
Antivalent (N.O. and N.C.)
Static
Dynamic
Off
1kHz / 0.5ms
500Hz / 1ms
250Hz / 2ms
100Hz / 5ms
50Hz / 10ms
20Hz / 25ms
Small
Standard
Large
(not available for M11/MV11 series)
Receiver
Pepperl+Fuchs Inc. • 1600 Enterprise Parkway • Twinsburg, Ohio 44087-2245 • www.am.pepperl-fuchs.com
Telephone (330) 486-0001 • FAX (330) 405-4710 • E-Mail: sales@us.pepperl-fuchs.com
®
Time function 1
Time function 2
Pulse frequency
Keypad locking
Input function
Input inverted
Parameterization disable
No
On delay (0.1s to 25.5s in 0.1s increments)
No
Off delay (0.1s to 25.5s in 0.1s increments)
Limit timer (pulse lengthener) (1ms to 255ms in
1ms increments)
One-shot (1ms to 255ms in 1ms increments)
Pulse Frequency 1
Pulse Frequency 2
Pulse Frequency 3
Off
Automatic
Always
None
Test function (not available for M11/MV11 series)
NC/NO-Switch-over
Logic AND
Logic OR
Logic XOR
Teach in (not available for M11/MV11 series)
Optical failure test (not available for M11/MV11
series)
Latch (not available for M11/MV11 series)
D-Flipflop (not available for M11/MV11 series)
All control input functions can be inverted
Off
On
Photoelectric Sensors
MLV11 Series Programming
(push-button tamper-proofing)
(not available for M11/MV11 series)
355