QH23SN6CV50 BANNER ENGINEERING, QH23SN6CV50 Datasheet - Page 5

Photoelectric Sensor

QH23SN6CV50

Manufacturer Part Number
QH23SN6CV50
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of QH23SN6CV50

Output Current
150mA
Sensor Output
NPN
Supply Voltage Range Dc
10V To 30V
Peak Reflow Compatible (260 C)
No
Sensor Housing
Rectangular
Sensor Input
Optical
Output Type
Transistor
Sensing Range Max
50mm
Quick Disconnect (QD) Option
Q23 & QH23 sensors are sold either with a 2 m (6.5 ft) or 9 m (30 ft) attached PVC-covered cable or with a 4-pin pico-style QD connector on a 150 mm
(6 in) cable pigtail.
Q23 & QH23 QD sensors are identified by the letter “Q” in their model number suffix. Mating cables for QD sensors are model PKG4-2 (straight connector)
or PKW4-2 (right-angled connector). Cables are supplied in a standard length of 2 m (6.5 ft). For more information on QD cable, see Accessories.
Supply Voltage and Current
0utput Configuration
Output Rating
Output Protection Circuitry
Output Response Time
Repeatability
Adjustments
Indicators
Construction
Environmental Rating
Connections
Operating Temperature
Application Note
Certifications
Supply Protection Circuitry
10 to 30V dc (10% maximum ripple) at less than 25 mA for diffuse, retro, and fiber optic models (exclusive of load)
Opposed emitters and receivers draw 20 mA each
Protected against reverse polarity and transient voltages
Solid-state dc complementary outputs:
Q(H)23SN6xx models = NPN sinking, N.O. (normally open) & N.C. (normally closed) complementary
Q(H)23SP6xx models = PNP sourcing, N.O. & N.C. complementary
Light operate: N.O. output conducts when the sensor sees its own modulated light source
Dark operate: N.C. output conducts when the sensing beam is blocked
The N.C. output may be used as an alarm output, depending upon hookup to the power supply (see
hookup diagrams)
150 mA maximum each in standard hookup; when wired for alarm output, the total load may not exceed 150 mA
Off-state leakage current less than 1 microamp at 30V dc
Output saturation voltage less than 1 volt at 10mA dc; less than 1.5V at 150 mA dc
Protected against false pulse on power-up, transient voltages, and continuous overload or short-circuit of outputs
1 millisecond “on” and “off” (except for Q23FPY high-speed sensors which have 100 microsecond
response time); no false pulse on power-up
(NOTE: 100 millisecond delay on power-up: outputs are non-conducting during this time.)
All Opposed Modes: 0.13 ms; Retro and Diffuse: 0.25 ms; FPY High speed Plastic Fiber Optic:
25 microseconds Response time and repeatability specifications are independent of signal strength.
SENSITIVITY control (single-turn, o-ring sealed potentiometer)
Sensors except opposed mode emitters have two LEDs:
GREEN glowing steadily = dc power “on”
GREEN flashing = output overload
YELLOW glowing steadily = normally open output is conducting
YELLOW flashing = marginal excess gain (1 - 1.5x), light condition; flashing YELLOW corresponds to
“on” state of alarm output
Emitters have green power “on” indicator
Yellow and black ABS housing, with acrylic lens and clear ABS top cover, completely sealed. Stainless steel
mounting bracket and M3 mounting hardware are supplied
Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 12, and 13; IEC IP67. Housing materials rated UL 94 V-0
PVC-jacketed 4-conductor 2 m (6.5 ft) or 9 m (30 ft) cables, or 6-inch pigtail with 4-pin pico-style quick
disconnect (QD) fitting are available. Mating QD cables are ordered separately. See Accessories.
Temperature: -20° to +55°C (-5° to +131°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
To avoid damage to the sensor caused by static discharge (ESD), use the plastic screwdriver supplied
with each sensor (included in the hardware packet) to adjust the SENSITIVITY control. Otherwise, use a
screwdriver with an insulated handle.
Q23 & QH23 Product Specifications
Q23 and QH23 Series